From: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
There are several Beckhoff Automation industrial PC boards which use pmc_plt_clk* clocks for ethernet controllers. The patch adds affected boards to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off. This should be applied on top of another patch as both change the same table: [PATCH] platform/x86: pmc_atom: Add Lex 3I380D industrial PC to critclk_systems DMI table
Steffen Dirkwinkel (1): platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
drivers/platform/x86/pmc_atom.c | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+)