Subject[PATCH 1/1] platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
Date
From: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>

There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
---
drivers/platform/x86/pmc_atom.c | 24 ++++++++++++++++++++++++
1 file changed, 24 insertions(+)

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index a311f48ce7c9..b1d804376237 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = {
DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
},
},
+ {
+ /* pmc_plt_clk* - are used for ethernet controllers */
+ .ident = "Beckhoff CB3163",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+ DMI_MATCH(DMI_BOARD_NAME, "CB3163"),
+ },
+ },
+ {
+ /* pmc_plt_clk* - are used for ethernet controllers */
+ .ident = "Beckhoff CB6263",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+ DMI_MATCH(DMI_BOARD_NAME, "CB6263"),
+ },
+ },
+ {
+ /* pmc_plt_clk* - are used for ethernet controllers */
+ .ident = "Beckhoff CB6363",
+ .matches = {
+ DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
+ DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
+ },
+ },
{ /*sentinel*/ }
};

--