lkml.org 
[lkml]   [2016]   [Jun]   [17]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 0/10] x86/tsc: fast calibration updates
On Fri, 17 Jun 2016, Len Brown wrote:

> Originally I wrote this series to increase TSC calibration
> accuracy and speed, but it now it also includes
> changes that are mandatory for some systems to work correctly.
> In particular, the Airmont table entires are already being
> used in products, and some BXT steppings will fail without
> the check added by patch 10.
>
> LKP tested this patch series in early April on top of 4.6-rc1
> and found a failure. That failure has been fixed
> upstream in 4.6 by commit 886123fb3a86
> (x86/tsc: Read all ratio bits from MSR_PLATFORM_INFO)
>
> So I have re-based the series on top of 4.7-rc3
> to take advantage of that fix, as well as to handle
> 3 merge conflicts due to intervening upstream commits.

Very nice work and good structured patches!

Reviewed-by: Thomas Gleixner <tglx@linutronix.de>

\
 
 \ /
  Last update: 2016-06-17 10:21    [W:0.261 / U:0.284 seconds]