lkml.org 
[lkml]   [2022]   [Aug]   [9]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 1/2] dt-bindings: hwmon: sparx5: use correct clock
Date
SparX-5 temperature sensor uses system reference clock and not the AHB bus
clock as indicated by the register information [1].

So, correct the clock description as well the included example.

[1] https://microchip-ung.github.io/sparx-5_reginfo/reginfo_sparx-5.html?select=hsiowrap,temp_sensor,temp_sensor_cfg,clk_cycles_1us

Fixes: f5520753c16f ("dt-bindings: hwmon: Add Sparx5 temperature sensor")
Signed-off-by: Robert Marko <robert.marko@sartura.hr>
---
.../devicetree/bindings/hwmon/microchip,sparx5-temp.yaml | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml b/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml
index 76be625d5646..51e8619dbf3c 100644
--- a/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml
+++ b/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml
@@ -22,7 +22,7 @@ properties:

clocks:
items:
- - description: AHB reference clock
+ - description: System reference clock

'#thermal-sensor-cells':
const: 0
@@ -40,5 +40,5 @@ examples:
compatible = "microchip,sparx5-temp";
reg = <0x10508110 0xc>;
#thermal-sensor-cells = <0>;
- clocks = <&ahb_clk>;
+ clocks = <&sys_clk>;
};
--
2.37.1
\
 
 \ /