Messages in this thread | | | Date | Tue, 9 Aug 2022 07:21:39 -0700 | From | Guenter Roeck <> | Subject | Re: [PATCH 1/2] dt-bindings: hwmon: sparx5: use correct clock |
| |
On Tue, Aug 09, 2022 at 01:22:08PM +0200, Robert Marko wrote: > SparX-5 temperature sensor uses system reference clock and not the AHB bus > clock as indicated by the register information [1]. > > So, correct the clock description as well the included example. > > [1] https://microchip-ung.github.io/sparx-5_reginfo/reginfo_sparx-5.html?select=hsiowrap,temp_sensor,temp_sensor_cfg,clk_cycles_1us > > Fixes: f5520753c16f ("dt-bindings: hwmon: Add Sparx5 temperature sensor") > Signed-off-by: Robert Marko <robert.marko@sartura.hr> > Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Applied.
Thanks, Guenter
> --- > .../devicetree/bindings/hwmon/microchip,sparx5-temp.yaml | 4 ++-- > 1 file changed, 2 insertions(+), 2 deletions(-) > > diff --git a/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml b/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml > index 76be625d5646..51e8619dbf3c 100644 > --- a/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml > +++ b/Documentation/devicetree/bindings/hwmon/microchip,sparx5-temp.yaml > @@ -22,7 +22,7 @@ properties: > > clocks: > items: > - - description: AHB reference clock > + - description: System reference clock > > '#thermal-sensor-cells': > const: 0 > @@ -40,5 +40,5 @@ examples: > compatible = "microchip,sparx5-temp"; > reg = <0x10508110 0xc>; > #thermal-sensor-cells = <0>; > - clocks = <&ahb_clk>; > + clocks = <&sys_clk>; > };
| |