SubjectRe: [PATCH 3/3] IO: hid-sensor-magn-3d: Add in support for True/Magnetic North HID usages
> +static void sensor_hub_fill_attr_info(
> + struct hid_sensor_hub_attribute_info *info,
> + s32 index, s32 report_id, struct hid_field *field)
> +{
> + info->index = index;
> + info->report_id = report_id;
> + info->units = field->unit;
> + info->unit_expo = field->unit_exponent;
> + info->size = (field->report_size * field->report_count)/8;
> + info->logical_minimum = field->logical_minimum;
> + info->logical_maximum = field->logical_maximum;
> }

I copied this function from hid/hid-sensor-hub.c as it is marked
static in that file. I use it to fill attributes as I find them.
Should I create an another patch to make it non-static?

> + list_for_each_entry(report, &report_enum->report_list, list) {
> + for (i = 0; i < report->maxfield; ++i) {
> + field = report->field[i];
> +
> + for (j = 0; j < field->maxusage; j++) {
> + usage = &(field->usage[j]);
> +

This is how I mange to find all possible hid reports in the parse
reports function. I noticed that in the other function that was used,
sensor_hub_input_get_attribute_info(), it only uses field->usage[0].
Is there a reason for this and should I change my current
implementation?


\
 
 \ /