Messages in this thread | | | Date | Fri, 3 Sep 2021 11:09:18 +0200 | From | Maxime Ripard <> | Subject | Re: [PATCH 3/8] clk: sunxi-ng: Use a separate lock for each CCU instance |
| |
On Wed, Sep 01, 2021 at 12:05:21AM -0500, Samuel Holland wrote: > Some platforms have more than one CCU driver loaded: the main CCU, the > PRCM, the display engine, and possibly others. All of these hardware > blocks have separate MMIO spaces, so there is no need to synchronize > between them. > > Signed-off-by: Samuel Holland <samuel@sholland.org>
Applied the first three patches
Maxime [unhandled content-type:application/pgp-signature] | |