Messages in this thread Patch in this message | | | From | Ajit Kumar Pandey <> | Subject | [PATCH v4 4/7] clk: x86: Use dynamic con_id string during clk registration | Date | Thu, 25 Nov 2021 16:34:44 +0530 |
| |
Replace hard coded con_id string with fch_data->name. We have clk consumers looking up with different clock names, hence use dynamic con_id string during clk lookup registration. fch_data->name will be initialized in acpi driver based on fmw property value.
Signed-off-by: Ajit Kumar Pandey <AjitKumar.Pandey@amd.com> --- drivers/clk/x86/clk-fch.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/x86/clk-fch.c b/drivers/clk/x86/clk-fch.c index de556b03e184..7c55e129779a 100644 --- a/drivers/clk/x86/clk-fch.c +++ b/drivers/clk/x86/clk-fch.c @@ -85,7 +85,7 @@ static int fch_clk_probe(struct platform_device *pdev) OSCCLKENB, CLK_GATE_SET_TO_DISABLE, NULL); devm_clk_hw_register_clkdev(&pdev->dev, hws[CLK_GATE_FIXED], - "oscout1", NULL); + fch_data->name, NULL); } pci_dev_put(rdev); -- 2.25.1
| |