| From | Florian Fainelli <> | Subject | Re: [PATCH 03/10] arm64: dts: broadcom: Fix SP805 clock-names | Date | Sun, 30 Aug 2020 20:57:08 -0700 |
| |
On Fri, 28 Aug 2020 14:05:55 +0100, Andre Przywara <andre.przywara@arm.com> wrote: > The SP805 binding sets the name for the actual watchdog clock to > "wdog_clk" (with an underscore). > > Change the name in the DTs for Broadcom platforms to match that. The > Linux and U-Boot driver use the *first* clock for this purpose anyway, > so it does not break anything. > > Signed-off-by: Andre Przywara <andre.przywara@arm.com> > ---
Applied to devicetree-arm64/next, thanks! -- Florian
|