Messages in this thread | | | Subject | Re: [PATCH 08/10] ARM: dts: Cygnus: Fix SP805 clocks | From | Florian Fainelli <> | Date | Sun, 30 Aug 2020 20:59:35 -0700 |
| |
On 8/30/2020 8:55 PM, Florian Fainelli wrote: > On Fri, 28 Aug 2020 14:06:00 +0100, Andre Przywara <andre.przywara@arm.com> wrote: >> The SP805 DT binding requires two clocks to be specified, but the >> Broadcom Cygnus DT currently only specifies one clock. >> >> In practice, Linux would pick a clock named "apb_pclk" for the bus >> clock, and the Linux and U-Boot SP805 driver would use the first clock >> to derive the actual watchdog counter frequency. >> >> Since currently both are the very same clock, we can just double the >> clock reference, and add the correct clock-names, to match the binding. >> >> Signed-off-by: Andre Przywara <andre.przywara@arm.com> >> --- > > Applied to qspi-fixes, thanks!
Applied to devicetree/next actually, likewise for the next patch. -- Florian
| |