Messages in this thread | | | Date | Thu, 29 Aug 2019 19:22:36 +0300 | From | Jarkko Sakkinen <> | Subject | Re: [PATCH v5 3/4] tpm: tpm_tis_spi: Introduce a flow control callback |
| |
On Wed, Aug 28, 2019 at 01:21:49AM -0700, Stephen Boyd wrote: > Cr50 firmware has a different flow control protocol than the one used by > this TPM PTP SPI driver. Introduce a flow control callback so we can > override the standard sequence with the custom one that Cr50 uses. > > Cc: Andrey Pronin <apronin@chromium.org> > Cc: Duncan Laurie <dlaurie@chromium.org> > Cc: Jason Gunthorpe <jgg@ziepe.ca> > Cc: Arnd Bergmann <arnd@arndb.de> > Cc: Greg Kroah-Hartman <gregkh@linuxfoundation.org> > Cc: Guenter Roeck <groeck@chromium.org> > Cc: Alexander Steffen <Alexander.Steffen@infineon.com> > Cc: Heiko Stuebner <heiko@sntech.de> > Signed-off-by: Stephen Boyd <swboyd@chromium.org>
Reviewed-by: Jarkko Sakkinen <jarkko.sakkinen@linux.intel.com>