Messages in this thread | | | From | Steve Twiss <> | Subject | RE: [PATCH 03/11] regulator: da9055: Convert to use regulator_set/get_current_limit_regmap | Date | Thu, 28 Feb 2019 15:18:07 +0000 |
| |
On 28 February 2019 13:40, Axel Lin,
> Subject: [PATCH 03/11] regulator: da9055: Convert to use > regulator_set/get_current_limit_regmap > > Use regulator_set/get_current_limit_regmap helpers to save some code.
[...]
> @@ -329,8 +298,8 @@ static const struct regulator_ops da9055_buck_ops = { > .get_mode = da9055_buck_get_mode, > .set_mode = da9055_buck_set_mode, > > - .get_current_limit = da9055_buck_get_current_limit, > - .set_current_limit = da9055_buck_set_current_limit, > + .get_current_limit = regulator_get_current_limit_regmap, > + .set_current_limit = regulator_set_current_limit_regmap, > > .get_voltage_sel = da9055_regulator_get_voltage_sel, > .set_voltage_sel = da9055_regulator_set_voltage_sel, > @@ -407,6 +376,10 @@ static const struct regulator_ops da9055_ldo_ops = { > .uV_step = (step) * 1000,\ > .linear_min_sel = (voffset),\ > .owner = THIS_MODULE,\ > + .curr_table = da9055_current_limits,\ > + .n_current_limits = ARRAY_SIZE(da9055_current_limits),\ > + .csel_reg = DA9055_REG_BUCK_LIM,\ > + .csel_mask = (mbits),\
Hi Axel,
Thanks.
Acked-by: Steve Twiss <stwiss.opensource@diasemi.com>
Regards, Steve
| |