SubjectRe: [PATCH 1/5] Documentation: DT: Add optional 'timeout-sec' property for sp805
On Tue, May 22, 2018 at 11:47:16AM -0700, Ray Jui wrote:
> Update the SP805 binding document to add optional 'timeout-sec'
> devicetree property
>
> Signed-off-by: Ray Jui <ray.jui@broadcom.com>
> Reviewed-by: Scott Branden <scott.branden@broadcom.com>

Reviewed-by: Guenter Roeck <linux@roeck-us.net>

> ---
> Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
> 1 file changed, 2 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> index edc4f0e..f898a86 100644
> --- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> +++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> @@ -19,6 +19,8 @@ Required properties:
>
> Optional properties:
> - interrupts : Should specify WDT interrupt number.
> +- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
> + default timeout is 30 seconds
>
> Examples:
>
> --
> 2.1.4
>

\
 
 \ /