On 22/05/18 19:47, Ray Jui wrote:
> Update the SP805 binding document to add optional 'timeout-sec'
> devicetree property
>
> Signed-off-by: Ray Jui <ray.jui@broadcom.com>
> Reviewed-by: Scott Branden <scott.branden@broadcom.com>
> ---
> Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
> 1 file changed, 2 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> index edc4f0e..f898a86 100644
> --- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> +++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
> @@ -19,6 +19,8 @@ Required properties:
>
> Optional properties:
> - interrupts : Should specify WDT interrupt number.
> +- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
> + default timeout is 30 seconds

According to the SP805 TRM, the default interval is dependent on the
rate of WDOGCLK, but would typically be a lot longer than that :/

On a related note, anyone have any idea why we seem to have two subtly
different SP805 bindings defined?

Robin.

>