Messages in this thread | | | From | Ivan Mironov <> | Subject | [PATCH 0/6] Add support of the HBA mode on HP Smart Array P410i controllers | Date | Fri, 14 Dec 2018 18:21:09 +0500 |
| |
This series of patches adds support of the HBA mode on HP Smart Array P410i RAID controllers.
This is not guaranteed to be correct as I do not have any access to documentation on these controllers. However, this works fine for me on hardware that I have. Also, these changes successfully passes blktests[1] and xfstests[2].
To make sure that this new functionality does not break anything, it is disabled by default and may be enabled only manually using new module parameter.
[1] https://github.com/osandov/blktests [2] https://git.kernel.org/pub/scm/fs/xfs/xfstests-dev.git
Ivan Mironov (6): scsi: hpsa: Add function to check if device is a disk or a zoned device scsi: hpsa: Support HBA mode on HP Smart Array P410i controllers scsi: hpsa: Add/mask existing devices on rescan if visibility changes scsi: hpsa: Ignore HBA flag from NVRAM if logical devices exist scsi: hpsa: Name more fields in "struct bmic_identify_controller" scsi: hpsa: Do not use HBA flag from NVRAM if HBA is not supported
drivers/scsi/hpsa.c | 145 ++++++++++++++++++++++++++++++++++++---- drivers/scsi/hpsa.h | 3 + drivers/scsi/hpsa_cmd.h | 113 ++++++++++++++++++++++++++++++- 3 files changed, 244 insertions(+), 17 deletions(-)
-- 2.19.2
| |