Messages in this thread | | | Date | Wed, 21 Jan 2015 15:35:40 -0800 | From | Guenter Roeck <> | Subject | Re: [PATCH 1/2] watchdog: dw_wdt: pat the watchdog before enabling it |
| |
On 01/21/2015 03:17 PM, Doug Anderson wrote: > On some dw_wdt implementations the "top" register may be initted to 0 > at bootup. In such a case, each "pat" of the watchdog will reset the > timer to 0xffff. That's pretty short. > > The input clock of the wdt can be any of a wide range of values. On > an rk3288 system, I've seen the wdt clock be 24.75 MHz. That means > each tick is ~40ns and we'll count to 0xffff in ~2.6ms. > > Because of the above two facts, it's a really good idea to pat the > watchdog after initting the "top" register properly and before > enabling the watchdog. If you don't then there's no way we'll get the > next heartbeat in time. > > Signed-off-by: Doug Anderson <dianders@chromium.org> > ---
Reviewed-by: Guenter Roeck <linux@roeck-us.net>
| |