lkml.org 
[lkml]   [2012]   [May]   [31]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
Subject[PATCH 1/2] regulator: wm831x-ldo: Use regulator_map_voltage_linear for wm831x_alive_ldo_ops
From
Date
wm831x_alive_ldo_ops uses simple linear voltage maps.
Thus use regulator_map_voltage_linear is more efficient than using the default
regulator_map_voltage_iterate.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
---
drivers/regulator/wm831x-ldo.c | 1 +
1 file changed, 1 insertion(+)

diff --git a/drivers/regulator/wm831x-ldo.c b/drivers/regulator/wm831x-ldo.c
index a9a28d8..f23d020e9 100644
--- a/drivers/regulator/wm831x-ldo.c
+++ b/drivers/regulator/wm831x-ldo.c
@@ -690,6 +690,7 @@ static int wm831x_alive_ldo_get_status(struct regulator_dev *rdev)

static struct regulator_ops wm831x_alive_ldo_ops = {
.list_voltage = regulator_list_voltage_linear,
+ .map_voltage = regulator_map_voltage_linear,
.get_voltage_sel = regulator_get_voltage_sel_regmap,
.set_voltage = wm831x_alive_ldo_set_voltage,
.set_suspend_voltage = wm831x_alive_ldo_set_suspend_voltage,
--
1.7.9.5




\
 
 \ /