Subject[2.6.0-test11] dpt/adaptec i2o trouble (long)
Date
Hi,

I own a dpt smart raid v (1554U2) scsi controller, for wich i used the
dpt_i2o driver under kernel 2.4, wich is currently broken in 2.6.
I googled a bit around, and found out that the suggested solution
is to use use the i2o-scsi driver:
http://marc.theaimsgroup.com/?l=linux-scsi&m=106046024506801&w=2
also see this thread:
http://marc.theaimsgroup.com/?t=106191158100004&r=1&w=2

So i compiled a fresh 2.6.0-test11 kernel, and build i2o-core, i2o-proc, i2o-scsi
and i2o-block as modules.
While modprobing i2o-core without parameters it told me:
"Skipping Adaptec/DPT I2O raid with preferred native driver."
with "dpt=1" the module loads, but it complains that it cant
get the size of the device:

--
Activating I2O controllers...
This may take a few minutes if there are many devices
i2o/iop0: LCT has 15 entries.
i2o_scsi.c: Version 0.1.2
chain_pool: 2048 bytes @ df1a7800
(512 byte buffers X 4 can_queue X 1 i2o controllers)
--> PARAMS_GET - Error:
--> ErrorInfoSize = 0x01, BlockStatus = 0x08, BlockSize = 0x0002
scsi1 : i2o/iop0
Vendor: IBM Model: DDRS-39130W Rev: S97B
Type: Direct-Access ANSI SCSI revision: 02
--> sda : READ CAPACITY failed.
--> sda : status=0, message=00, host=7, driver=00
--> sda : sense not available.
SCSI device sda: drive cache: write back
sda: sda1
Attached scsi disk sda at scsi1, channel 0, id 2, lun 0
Attached scsi generic sg1 at scsi1, channel 0, id 2, lun 0, type 0
--

in this state fdisk tells me the following:

--
Disk /dev/sda: 1073 MB, 1073741824 bytes
255 heads, 63 sectors/track, 130 cylinders
Units = cylinders of 16065 * 512 = 8225280 bytes

Device Boot Start End Blocks Id System
/dev/sda1 1 1111 8924076 83 Linux
Partition 1 has different physical/logical endings:
phys=(1023, 254, 63) logical=(1110, 254, 63)
--

which is wrong, because the attached harddisk
(i dont use the raid features of this controller) is
an ibm ddrs-39130w -> size = 9.1 gb

on 2.4, using the dpt_i2o driver, i dont experience
this problems:

--
Loading Adaptec I2O RAID: Version 2.4 Build 5
Detecting Adaptec I2O RAID controllers...
PCI: Found IRQ 5 for device 00:0d.1
Adaptec I2O RAID controller 0 at e14b0000 size=100000 irq=5
dpti: If you have a lot of devices this could take a few minutes.
dpti0: Reading the hardware resource table.
TID 008 Vendor: SYMBIOS Device: SYM53C895 Rev: 00000001
TID 515 Vendor: IBM Device: DDRS-39130W Rev: S97B
scsi2 : Vendor: Adaptec Model: PM1554U2 FW:3013
Vendor: IBM Model: DDRS-39130W Rev: S97B
Type: Direct-Access ANSI SCSI revision: 02
Attached scsi disk sda at scsi2, channel 0, id 2, lun 0
SCSI device sda: 17849983 512-byte hdwr sectors (9139 MB)
sda: sda1
--

i´ve put up further information (log entries,...) here:
http://segfault.info/simon/i2o/

my .config:
http://segfault.info/simon/i2o/2.6.0-test11.config

best regards,
simon.

-
To unsubscribe from this list: send the line "unsubscribe linux-kernel" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at http://vger.kernel.org/majordomo-info.html
Please read the FAQ at http://www.tux.org/lkml/

\
 
 \ /
  Last update: 2005-03-22 13:59    [W:0.280 / U:0.040 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site