Messages in this thread | ![/](/images/icornerl.gif) | | Date | Tue, 24 Jan 2023 17:54:52 +0100 | Subject | Re: [PATCH v7 4/4] thermal: mediatek: add another get_temp ops for thermal sensors | From | Daniel Lezcano <> |
| |
Hi Amjad,
On 24/01/2023 11:08, Amjad Ouled-Ameur wrote:
[ ... ]
>>> >>> IIUC, there is a sensor per couple of cores. 1 x 2Bigs, 1 x 2Bigs, 1 >>> x 4 Little, right ? >> >> MT8365 SoC has 4 x A53 CPUs. The SoC has 4 thermal zones per sensor. >> Thermal zone 0 corresponds >> >> to all 4 x A53 CPUs, the other thermal zones (1, 2 and 3) has nothing >> to do with CPUs. The cooling device type >> >> used for CPUs is passive. FYI, thermal zones 1, 2 and 3 are present in >> the SoC for debug-purpose only, they are not supposed >> >> to be used for production. >> > After reconsidering the fact that zones 1, 2 and 3 are only used for > dev/debug, it might be best to avo > > aggregation as you suggested, and keep only support for zone 0 in this > driver. Thus I suggest I send a V8 > > where I keep only below fixes for this patch if that's okay with you: > > - Define "raw_to_mcelsius" function pointer for "struct thermal_bank_cfg". > > - Fix "mtk_thermal" variable in mtk_read_temp(). > > - Set "mt->raw_to_mcelsius" in probe(). > > > For zones 1, 2 and 3 we can later add a different driver specific for > dev/debug to probe them to > > avoid confusion.
You can add them in the driver and in the device tree, but just add the cooling device for the thermal zone 0.
-- <http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs