Messages in this thread Patch in this message | | | From | Guido Günther <> | Subject | [PATCH 5/5] leds: lm3692x: Use flags from LM3692X_BRT_CTRL | Date | Tue, 17 Sep 2019 19:19:58 -0700 |
| |
Use LM3692X_RAMP_EN instead of LM3692X_PWM_HYSTER_4LSB since the later is a flag for the PWM register. The actual register value remains unchanged.
Signed-off-by: Guido Günther <agx@sigxcpu.org> --- drivers/leds/leds-lm3692x.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/leds/leds-lm3692x.c b/drivers/leds/leds-lm3692x.c index d673f706385e..ecac586ca89c 100644 --- a/drivers/leds/leds-lm3692x.c +++ b/drivers/leds/leds-lm3692x.c @@ -269,7 +269,7 @@ static int lm3692x_init(struct lm3692x_led *led) goto out; ret = regmap_write(led->regmap, LM3692X_BRT_CTRL, - LM3692X_BL_ADJ_POL | LM3692X_PWM_HYSTER_4LSB); + LM3692X_BL_ADJ_POL | LM3692X_RAMP_EN); if (ret) goto out; -- 2.23.0.rc1
| |