Messages in this thread Patch in this message | | | From | Andi Shyti <> | Subject | [PATCH] spi: s3c64xx: fix inconsistency between binding and driver | Date | Tue, 07 Feb 2017 17:07:48 +0900 |
| |
Commit a92e7c3d82a1 ("spi: s3c64xx: consider the case when the CS line is not connected") introduced an inconsistency between the binding where the disconnected CS line was marked as 'no-cs-readback' while the driver was erroneously checking for 'broken-cs'.
Check for 'no-cs-readback' in the driver as well.
Signed-off-by: Andi Shyti <andi.shyti@samsung.com> --- drivers/spi/spi-s3c64xx.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/spi/spi-s3c64xx.c b/drivers/spi/spi-s3c64xx.c index b8cd356d8d10..b392cca8fa4f 100644 --- a/drivers/spi/spi-s3c64xx.c +++ b/drivers/spi/spi-s3c64xx.c @@ -969,7 +969,7 @@ static struct s3c64xx_spi_info *s3c64xx_spi_parse_dt(struct device *dev) sci->num_cs = temp; } - sci->no_cs = of_property_read_bool(dev->of_node, "broken-cs"); + sci->no_cs = of_property_read_bool(dev->of_node, "no-cs-readback"); return sci; } -- 2.11.0
| |