lkml.org 
[lkml]   [2015]   [Aug]   [5]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 0/8] watchdog: Add support for keepalives triggered by infrastructure
On Mon, Aug 03, 2015 at 07:13:26PM -0700, Guenter Roeck wrote:
> - Some watchdogs have a very short maximum timeout, in the range of just a few
> seconds. Such low timeouts are difficult if not impossible to support from
> user space. Drivers supporting such watchdog hardware need to implement
> a timer function to augment heartbeats from user space.

> - A new status flag, WDOG_RUNNING, informs the watchdog subsystem that a
> watchdog is running, and that the watchdog subsystem needs to generate
> heartbeat requests while the associated watchdog device is closed.

> Patch #2 adds timer functionality to the watchdog core. It solves the problem
> of short maximum hardware timeouts by augmenting heartbeats triggered from
> user space with internally triggered heartbeats.
>
> Patch #3 adds functionality to generate heartbeats while the watchdog device is
> closed. It handles situation where where the watchdog is running after
> the driver has been instantiated, but the device is not yet opened,
> and post-close situations necessary if a watchdog can not be stopped.

These sound concerning because it seems that heartbeats could be generated
outside of the direct control of userspace. I have a program that depends
on having direct control over whether heartbeats are generated (or more
specifically, *not* generated.) If these new features introduce a new way
for heartbeats to be generated, is there a way I can detect or disable
that behavior from userspace? Unwanted heartbeats could break my program
and may lead to data corruption.

A related issue from some years ago is the unfortunate fact that closing
the watchdog device also generates a heartbeat. I'd like to disable that
also, and submitted a patch for it here:
http://www.spinics.net/lists/linux-watchdog/msg01477.html

(Without the patch, I have to work around it by closing the device
prematurely as a way to generate the potentially final heartbeat, and then
reopen it again if I want to continue the heartbeats.)

Dave


\
 
 \ /
  Last update: 2015-08-05 19:41    [W:0.320 / U:0.228 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site