lkml.org 
[lkml]   [2008]   [Mar]   [21]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH] x86: traps_32.c - use KSYM_NAME_LEN instead of numeric value

* Cyrill Gorcunov <gorcunov@gmail.com> wrote:

> It's safer to use KSYM_NAME_LEN instead of numeric constant because we
> could get buffer overrun someday if KSYM_NAME_LEN would be changed to
> a bigger value.

thanks, applied.

Ingo


\
 
 \ /