SubjectRe: [PATCH v4 07/17] iio: magnetometer: ak8975: pass conversion timeouts as arguments
On Mon, 4 May 2026 at 11:48, Joshua Crofts via B4 Relay
<devnull+joshua.crofts1.gmail.com@kernel.org> wrote:
> @@ -708,6 +705,11 @@ static int wait_conversion_complete_interrupt(struct ak8975_data *data)
> static int ak8975_start_read_axis(struct ak8975_data *data,
> const struct i2c_client *client)
> {
> + int irq_timeout_ms = 100;
> + int timeout_ms = 500;
> + int poll_ms = 10;
> + int ret;
> +
> /* Set up the device for taking a sample. */
> int ret = ak8975_set_mode(data, MODE_ONCE);

BTW, also noticed a redefinition error here.

--