Messages in this thread |  | | Date | Wed, 3 Sep 2025 10:52:57 -0700 | | Subject | Re: [PATCH RFC v3 14/15] block: fix disordered IO in the case recursive split | | From | Bart Van Assche <> |
| |
On 9/3/25 9:59 AM, Yu Kuai wrote: > 在 2025/9/3 21:34, Christoph Hellwig 写道: >>> + if (split && !bdev_is_zoned(bio->bi_bdev)) >> >> Why are zoned devices special cased here? >> > I'm not that sure about zoned device before, I'll remove this checking, > and mention the problem Bart met in commit message in the next version.
If I keep the bdev_is_zoned() check, test zbd/014 fails. If I remove it, test zbd/014 passes. I think that's a strong argument to remove that check. Test zbd/014 is not yet in the blktests repository but is available here: https://lore.kernel.org/linux-block/a8a714c7-de3d-4cc9-8c23-38b8dc06f5bb@acm.org/
Thanks,