Messages in this thread |  | | Date | Tue, 2 Dec 2025 12:48:47 +0000 | | From | "Russell King (Oracle)" <> | | Subject | Re: [PATCH net-next v2 1/1] net: mdio: reset PHY before attempting to access ID register |
| |
On Tue, Dec 02, 2025 at 01:38:21PM +0100, Paolo Abeni wrote: > On 11/28/25 2:53 PM, Buday Csaba wrote: > > When the ID of an Ethernet PHY is not provided by the 'compatible' > > string in the device tree, its actual ID is read via the MDIO bus. > > For some PHYs this could be unsafe, since a hard reset may be > > necessary to safely access the MDIO registers. > > > > Add a fallback mechanism for such devices: when reading the ID > > fails, the reset will be asserted, and the ID read is retried. > > > > This allows such devices to be used with an autodetected ID. > > > > The fallback mechanism is activated in the error handling path, and > > the return code of fwnode_mdiobus_register_phy() is unaltered, except > > when the reset fails with -EPROBE_DEFER, which is propagated to the > > caller. > > > > Signed-off-by: Buday Csaba <buday.csaba@prolan.hu> > > IMHO this deserves an explicit ack from phy maintainers. Unless such ack > is going to land on the ML very soon, I suggest to defer this patch to > the next cycle, as Jakub is wrapping the net-next PR.
No time to do anything quickly, sorry.