SubjectRe: [PATCH v2 2/2] iio: light: Add support for APDS9306 Light Sensor
From
On 11/6/23 14:04, Subhajit Ghosh wrote:
> On 6/11/23 21:43, Jonathan Cameron wrote:
>> On Tue, 31 Oct 2023 19:08:08 +1030
>> Subhajit Ghosh <subhajit.ghosh@tweaklogic.com> wrote:
>>
>>>> Scale on the intensity channel is interesting...  What are the units?
>>>> There tend not to be any well defined units for intensity (as opposed
>>>> to illuminance).  There may be gain on the signal, but it won't be
>>>> in untils
>>>> that map directly to a scale userspace should apply.  This is one of
>>>> the
>>>> rare reasons for using the HARDWARE_GAIN element of the ABI.
>>>>
>>>> A tricky corner however as relationship between raw value and
>>>> hardwaregain
>>>> is not tightly defined (as it can be really weird!)
>>> Hi Jonathan,
>>>
>>> Thank you for taking time for reviewing and clearing all my tiny
>>> doubts and
>>> queries especially for the dt and versioning part. Much appreciated.
>>>
>>> In the above case, should I not expose scale for the "clear" channel?
>>> Rather,
>>> how should I expose the "clear" channel to userspace?
>> What is the scale?  What units to you get after applying it?
> The scale is in Lux. The output after applying is Lux.

Hi Subhajit,

I am by no means an expert here but maybe you could check if the channel
should be of type 'illuminance'? (To me 'Lux' sounds like an unit of
illuminance rather than intensity).

Yours,
-- Matti

--