Messages in this thread | | | Date | Mon, 6 Nov 2023 14:10:43 +0200 | Subject | Re: [PATCH v2 2/2] iio: light: Add support for APDS9306 Light Sensor | From | Matti Vaittinen <> |
| |
On 11/6/23 14:04, Subhajit Ghosh wrote: > On 6/11/23 21:43, Jonathan Cameron wrote: >> On Tue, 31 Oct 2023 19:08:08 +1030 >> Subhajit Ghosh <subhajit.ghosh@tweaklogic.com> wrote: >> >>>> Scale on the intensity channel is interesting... What are the units? >>>> There tend not to be any well defined units for intensity (as opposed >>>> to illuminance). There may be gain on the signal, but it won't be >>>> in untils >>>> that map directly to a scale userspace should apply. This is one of >>>> the >>>> rare reasons for using the HARDWARE_GAIN element of the ABI. >>>> >>>> A tricky corner however as relationship between raw value and >>>> hardwaregain >>>> is not tightly defined (as it can be really weird!) >>> Hi Jonathan, >>> >>> Thank you for taking time for reviewing and clearing all my tiny >>> doubts and >>> queries especially for the dt and versioning part. Much appreciated. >>> >>> In the above case, should I not expose scale for the "clear" channel? >>> Rather, >>> how should I expose the "clear" channel to userspace? >> What is the scale? What units to you get after applying it? > The scale is in Lux. The output after applying is Lux.
Hi Subhajit,
I am by no means an expert here but maybe you could check if the channel should be of type 'illuminance'? (To me 'Lux' sounds like an unit of illuminance rather than intensity).
Yours, -- Matti
-- Matti Vaittinen Linux kernel developer at ROHM Semiconductors Oulu Finland