Hi Konrad,
On 7/15/22 8:26 PM, Konrad Dybcio <konrad.dybcio@somainline.org> wrote: > > > On 1.07.2022 16:58, Bhupesh Sharma wrote: > > Since for some QCoM tsens controllers, its suggested to > > monitor the controller health periodically and in case an > > issue is detected, to re-initialize the tsens controller > > via trustzone, add the support for the same in the > > qcom tsens driver. > > > > Note that Once the tsens controller is reset using scm call, > > all SROT and TM region registers will enter the reset mode. > > > > While all the SROT registers will be re-programmed and > > re-enabled in trustzone prior to the scm call exit, the TM > > region registers will not re-initialized in trustzone and thus > > need to be handled by the tsens driver. > > > > Cc: Amit Kucheria <amitk@kernel.org> > > Cc: Thara Gopinath <thara.gopinath@gmail.com> > > Cc: linux-pm@vger.kernel.org > > Cc: linux-arm-msm@vger.kernel.org > > Signed-off-by: Bhupesh Sharma <bhupesh.sharma@linaro.org> > > Reported-by: kernel test robot <lkp@intel.com> > > --- > Hi, I think this should be also checked and applied on init. This > seems required for at least SM6375, as the controller starts (or > well, doesn't start...) in an unknown state and the driver does > not like it, as the TSENS_EN indicates it is disabled. > Downstream runs this right at probe..
Hmm.. very interesting. I was not aware of the SM6375 case, as for SM8150 the controller starts in a valid state but may require reinit during operation.
So, I did not use the downstream approach to do it right at _probe() and then later while get_temp() is called.
Let me add that in v2. BTW do you want me to set the need_reinit_wa as true for SM6375 as well, or would you like to add that with a followup-patch ?
Regards, Bhupesh
| |