Messages in this thread | | | Subject | Re: [smartpqi updates PATCH V2 05/11] smartpqi: add tur check for sanitize operation | From | Paul Menzel <> | Date | Wed, 29 Sep 2021 09:56:34 +0200 |
| |
Dear Don,
Thank you for the patch. Maybe rephrase the summary:
> Check TUR for sanitize operation
Am 29.09.21 um 01:54 schrieb Don Brace: > Add in a TUR to HBA disks and do not present them to the OS if
Maybe add what TUR means: Test Unit Ready.
> 0x02/0x04/0x1b (sanitize in progress) is returned. > > During boot-up, some OSes appear to hang when there are one or > more disks undergoing sanitize.
It’d be great, if you gave at least one concrete test setup, where the hang occurred.
> According to SCSI SBC4 specification > section 4.11.2 Commands allowed during sanitize, > some SCSI commands are permitted, but read/write operations are not. > > When the OS attempts to read the disk partition table a > CHECK CONDITION ASC 0x04 ASCQ 0x1b is returned which causes the OS > to retry the read until sanitize has completed. This can take hours. > > Note: According to document HPE Smart Storage Administrator User Guide > Link: https://support.hpe.com/hpesc/public/docDisplay?docLocale=en_US&docId=c03909334 > > During the sanitize erase operation, the drive is unusable. > I.E. > The expected behavior for sanitize is the that disk remains > offline even after sanitize has completed. The customer is > expected to re-enable the disk using the management utility. > > Reviewed-by: Scott Benesh <scott.benesh@microchip.com> > Reviewed-by: Scott Teel <scott.teel@microchip.com> > Reviewed-by: Mike McGowen <mike.mcgowen@microchip.com> > Signed-off-by: Don Brace <don.brace@microchip.com> > --- > drivers/scsi/smartpqi/smartpqi_init.c | 87 +++++++++++++++++++++++++++ > 1 file changed, 87 insertions(+) > > diff --git a/drivers/scsi/smartpqi/smartpqi_init.c b/drivers/scsi/smartpqi/smartpqi_init.c > index 01330fd67500..838274d8fadf 100644 > --- a/drivers/scsi/smartpqi/smartpqi_init.c > +++ b/drivers/scsi/smartpqi/smartpqi_init.c > @@ -555,6 +555,10 @@ static int pqi_build_raid_path_request(struct pqi_ctrl_info *ctrl_info, > cdb = request->cdb; > > switch (cmd) { > + case TEST_UNIT_READY: > + request->data_direction = SOP_READ_FLAG; > + cdb[0] = TEST_UNIT_READY; > + break; > case INQUIRY: > request->data_direction = SOP_READ_FLAG; > cdb[0] = INQUIRY; > @@ -1575,6 +1579,85 @@ static int pqi_get_logical_device_info(struct pqi_ctrl_info *ctrl_info, > return rc; > } > > +/* > + * Prevent adding drive to OS for some corner cases such as a drive > + * undergoing a sanitize operation. Some OSes will continue to poll > + * the drive until the sanitize completes, which can take hours, > + * resulting in long bootup delays. Commands such as TUR, READ_CAP > + * are allowed, but READ/WRITE cause check condition. So the OS > + * cannot check/read the partition table. > + * Note: devices that have completed sanitize must be re-enabled > + * using the management utility. > + */ > +static bool pqi_keep_device_offline(struct pqi_ctrl_info *ctrl_info, > + struct pqi_scsi_dev *device) > +{ > + u8 scsi_status; > + int rc; > + enum dma_data_direction dir; > + char *buffer; > + int buffer_length = 64;
Use size_t? And could be made const?
> + size_t sense_data_length; > + struct scsi_sense_hdr sshdr; > + struct pqi_raid_path_request request; > + struct pqi_raid_error_info error_info; > + bool offline = false; /* Assume keep online */ > + > + /* Do not check controllers. */
I’d remove the dot/period at the end of the short comments.
> + if (pqi_is_hba_lunid(device->scsi3addr)) > + return false; > + > + /* Do not check LVs. */ > + if (pqi_is_logical_device(device)) > + return false; > + > + buffer = kmalloc(buffer_length, GFP_KERNEL); > + if (!buffer) > + return false; /* Assume not offline */ > + > + /* Check for SANITIZE in progress using TUR */ > + rc = pqi_build_raid_path_request(ctrl_info, &request, > + TEST_UNIT_READY, RAID_CTLR_LUNID, buffer, > + buffer_length, 0, &dir); > + if (rc) > + goto out; /* Assume not offline */ > + > + memcpy(request.lun_number, device->scsi3addr, sizeof(request.lun_number)); > + > + rc = pqi_submit_raid_request_synchronous(ctrl_info, &request.header, 0, &error_info); > + > + if (rc) > + goto out; /* Assume not offline */ > + > + scsi_status = error_info.status; > + sense_data_length = get_unaligned_le16(&error_info.sense_data_length); > + if (sense_data_length == 0) > + sense_data_length = > + get_unaligned_le16(&error_info.response_data_length);
As the variable is named `sense_data_length`, for an outsider like me, it’s suprising that `response_date_length` is stored in there.
> + if (sense_data_length) { > + if (sense_data_length > sizeof(error_info.data)) > + sense_data_length = sizeof(error_info.data); > + > + /* > + * Check for sanitize in progress: asc:0x04, ascq: 0x1b
Add a space after the second colon?
> + */ > + if (scsi_status == SAM_STAT_CHECK_CONDITION && > + scsi_normalize_sense(error_info.data, > + sense_data_length, &sshdr) && > + sshdr.sense_key == NOT_READY && > + sshdr.asc == 0x04 && > + sshdr.ascq == 0x1b) { > + device->device_offline = true; > + offline = true; > + goto out; /* Keep device offline */ > + } > + }
Should a error, warning, or debug message be printed, when `sense_data_length = 0` again?
> + > +out: > + kfree(buffer); > + return offline; > +} > + > static int pqi_get_device_info(struct pqi_ctrl_info *ctrl_info, > struct pqi_scsi_dev *device, > struct bmic_identify_physical_device *id_phys) > @@ -2296,6 +2379,10 @@ static int pqi_update_scsi_devices(struct pqi_ctrl_info *ctrl_info) > if (!pqi_is_supported_device(device)) > continue; > > + /* Do not present disks that the OS cannot fully probe */ > + if (pqi_keep_device_offline(ctrl_info, device))
I’d use the positive `!pqi_get_device_online()`, but it’s subjective.
> + continue; > + > /* Gather information about the device. */ > rc = pqi_get_device_info(ctrl_info, device, id_phys); > if (rc == -ENOMEM) { >
Kind regards,