On Mon, 20 Sep 2021 16:49:44 +0200, Krzysztof Kozlowski wrote:
> The SiFive FU740 Power Reset Clock Interrupt Controller is a reset line
> provider so add respective reset-cells property to fix:
>
> arch/riscv/boot/dts/sifive/hifive-unmatched-a00.dt.yaml: clock-controller@10000000:
> '#reset-cells' does not match any of the regexes: 'pinctrl-[0-9]+'
>
> Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
> ---
> .../devicetree/bindings/clock/sifive/fu740-prci.yaml | 4 ++++
> 1 file changed, 4 insertions(+)
>

Reviewed-by: Rob Herring <robh@kernel.org>

\
 
 \ /