lkml.org 
[lkml]   [2021]   [Aug]   [2]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH 0/4] Add multi-cid support for vsock driver
On Mon, Aug 02, 2021 at 08:07:16PM +0800, fuguancheng wrote:
>This patchset enables the user to specify additional CIDS for host and
>guest when booting up the guest machine. The guest's additional CIDS cannot
>be repeated, and can be used to communicate with the host. The user can
>also choose to specify a set of additional host cids, which can be
>used to communicate with the guest who specify them. The original
>CID(VHOST_DEFAULT_CID) is still available for host. The guest cid field is
>deleted.
>
>To ensure that multiple guest CID maps to the same vhost_vsock struct,
>a struct called vhost_vsock_ref is added. The function of vhost_vsock_ref
>is simply used to allow multiple guest CIDS map to the
>same vhost_vsock struct.
>
>If not specified, the host and guest will now use the first CID specified
>in the array for connect operation. If the host or guest wants to use
>one specific CID, the bind operation can be performed before the connect
>operation so that the vsock_auto_bind operation can be avoided.
>
>Hypervisors such as qemu needs to be modified to use this feature. The
>required changes including at least the following:
>1. Invoke the modified ioctl call with the request code
>VHOST_VSOCK_SET_GUEST_CID. Also see struct multi_cid_message for
>arguments used in this ioctl call.
>2. Write new arguments to the emulated device config space.
>3. Modify the layout of the data written to the device config space.
>See struct virtio_vsock_config for reference.

Can you please describe a use case?

vsock was created to be zero configuration, we're complicating enough
here, we should have a particular reason.

Also I gave a quick view and it seems to me that you change
virtio_vsock_config, are you sure it works if one of the two peers
doesn't support multiple CIDs?

Maybe we'd need a new feature bit, and we'd definitely need to discuss
specification changes with virtio-comment@lists.oasis-open.org first.

How does the guest or host applications know which CIDs are assigned to
them?

Please use the RFC tag if the patches are not in good shape.
Patches seem hard to review, please avoid adding code that is removed
later (e.g. multi_cid_message), and try not to break the backward
compatibility.

Thanks,
Stefano

\
 
 \ /
  Last update: 2021-08-02 15:44    [W:0.071 / U:0.408 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site