Hello,
On Thu, Jun 10, 2021 at 6:10 AM Andrew Lunn <andrew@lunn.ch> wrote: > > On Wed, Jun 09, 2021 at 07:43:42PM -0500, praneeth@ti.com wrote: > > From: Praneeth Bajjuri <praneeth@ti.com> > > > > Current logic is performing hard reset and causing the programmed > > registers to be wiped out. > > > > as per datasheet: https://www.ti.com/lit/ds/symlink/dp83867cr.pdf > > 8.6.26 Control Register (CTRL) > > > > do SW_RESTART to perform a reset not including the registers, > > If performed when link is already present, > > it will drop the link and trigger re-auto negotiation. > > > > Signed-off-by: Praneeth Bajjuri <praneeth@ti.com> > > Signed-off-by: Geet Modi <geet.modi@ti.com> > > Reviewed-by: Andrew Lunn <andrew@lunn.ch> > > Andrew
I reported a few days ago an issue with the DP83822 which I think is caused by a similar change. https://lore.kernel.org/netdev/CAHvQdo2yzJC89K74c_CZFjPydDQ5i22w36XPR5tKVv_W8a2vcg@mail.gmail.com/ In my case I can't get an link after this change, reverting it fixes the problem for me.
Hannes
| |