SubjectRe: [PATCH] net: phy: fix PHY possibly unwork after MDIO bus resume back
Date
On 06.04.2021 04:07, Joakim Zhang wrote:
>
> Hi Heiner,
>
>> -----Original Message-----
>> From: Heiner Kallweit <hkallweit1@gmail.com>
>> Sent: 2021年4月5日 20:10
>> To: christian.melki@t2data.com; Joakim Zhang <qiangqing.zhang@nxp.com>;
>> andrew@lunn.ch; linux@armlinux.org.uk; davem@davemloft.net;
>> kuba@kernel.org
>> Cc: netdev@vger.kernel.org; linux-kernel@vger.kernel.org; dl-linux-imx
>> <linux-imx@nxp.com>
>> Subject: Re: [PATCH] net: phy: fix PHY possibly unwork after MDIO bus resume
>> back
>>
>> On 05.04.2021 10:43, Christian Melki wrote:
>>> On 4/5/21 12:48 AM, Heiner Kallweit wrote:
>>>> On 04.04.2021 16:09, Heiner Kallweit wrote:
>>>>> On 04.04.2021 12:07, Joakim Zhang wrote:
>>>>>> commit 4c0d2e96ba055 ("net: phy: consider that suspend2ram may cut
>>>>>> off PHY power") invokes phy_init_hw() when MDIO bus resume, it will
>>>>>> soft reset PHY if PHY driver implements soft_reset callback.
>>>>>> commit 764d31cacfe4 ("net: phy: micrel: set soft_reset callback to
>>>>>> genphy_soft_reset for KSZ8081") adds soft_reset for KSZ8081. After
>>>>>> these two patches, I found i.MX6UL 14x14 EVK which connected to
>>>>>> KSZ8081RNB doesn't work any more when system resume back, MAC
>> driver is fec_main.c.
>>>>>>
>>>>>> It's obvious that initializing PHY hardware when MDIO bus resume
>>>>>> back would introduce some regression when PHY implements
>>>>>> soft_reset. When I
>>>>>
>>>>> Why is this obvious? Please elaborate on why a soft reset should
>>>>> break something.
>>>>>
>>>>>> am debugging, I found PHY works fine if MAC doesn't support
>>>>>> suspend/resume or phy_stop()/phy_start() doesn't been called during
>>>>>> suspend/resume. This let me realize, PHY state machine
>>>>>> phy_state_machine() could do something breaks the PHY.
>>>>>>
>>>>>> As we known, MAC resume first and then MDIO bus resume when system
>>>>>> resume back from suspend. When MAC resume, usually it will invoke
>>>>>> phy_start() where to change PHY state to PHY_UP, then trigger the
>>>>>> stat> machine to run now. In phy_state_machine(), it will
>>>>>> start/config auto-nego, then change PHY state to PHY_NOLINK, what
>>>>>> to next is periodically check PHY link status. When MDIO bus
>>>>>> resume, it will initialize PHY hardware, including soft_reset, what
>>>>>> would soft_reset affect seems various from different PHYs. For
>>>>>> KSZ8081RNB, when it in PHY_NOLINK state and then perform a soft reset,
>> it will never complete auto-nego.
>>>>>
>>>>> Why? That would need to be checked in detail. Maybe chip errata
>>>>> documentation provides a hint.
>>>>>
>>>>
>>>> The KSZ8081 spec says the following about bit BMCR_PDOWN:
>>>>
>>>> If software reset (Register 0.15) is
>>>> used to exit power-down mode
>>>> (Register 0.11 = 1), two software
>>>> reset writes (Register 0.15 = 1) are
>>>> required. The first write clears
>>>> power-down mode; the second
>>>> write resets the chip and re-latches
>>>> the pin strapping pin values.
>>>>
>>>> Maybe this causes the issue you see and genphy_soft_reset() isn't
>>>> appropriate for this PHY. Please re-test with the KSZ8081 soft reset
>>>> following the spec comment.
>>>>
>>>
>>> Interesting. Never expected that behavior.
>>> Thanks for catching it. Skimmed through the datasheets/erratas.
>>> This is what I found (micrel.c):
>>>
>>> 10/100:
>>> 8001 - Unaffected?
>>> 8021/8031 - Double reset after PDOWN.
>>> 8041 - Errata. PDOWN broken. Recommended do not use. Unclear if reset
>>> solves the issue since errata says no error after reset but is also
>>> claiming that only toggling PDOWN (may) or power will help.
>>> 8051 - Double reset after PDOWN.
>>> 8061 - Double reset after PDOWN.
>>> 8081 - Double reset after PDOWN.
>>> 8091 - Double reset after PDOWN.
>>>
>>> 10/100/1000:
>>> Nothing in gigabit afaics.
>>>
>>> Switches:
>>> 8862 - Not affected?
>>> 8863 - Errata. PDOWN broken. Reset will not help. Workaround exists.
>>> 8864 - Not affected?
>>> 8873 - Errata. PDOWN broken. Reset will not help. Workaround exists.
>>> 9477 - Errata. PDOWN broken. Will randomly cause link failure on
>>> adjacent links. Do not use.
>>>
>>> This certainly explains a lot.
>>>
>>>>>>
>>>>>> This patch changes PHY state to PHY_UP when MDIO bus resume back,
>>>>>> it should be reasonable after PHY hardware re-initialized. Also
>>>>>> give state machine a chance to start/config auto-nego again.
>>>>>>
>>>>>
>>>>> If the MAC driver calls phy_stop() on suspend, then
>>>>> phydev->suspended is true and mdio_bus_phy_may_suspend() returns
>>>>> false. As a consequence
>>>>> phydev->suspended_by_mdio_bus is false and mdio_bus_phy_resume()
>>>>> skips the PHY hw initialization.
>>>>> Please also note that mdio_bus_phy_suspend() calls
>>>>> phy_stop_machine() that sets the state to PHY_UP.
>>>>>
>>>>
>>>> Forgot that MDIO bus suspend is done before MAC driver suspend.
>>>> Therefore disregard this part for now.
>>>>
>>>>> Having said that the current argumentation isn't convincing. I'm not
>>>>> aware of such issues on other systems, therefore it's likely that
>>>>> something is system-dependent.
>>>>>
>>>>> Please check the exact call sequence on your system, maybe it
>>>>> provides a hint.
>>>>>
>>>>>> Signed-off-by: Joakim Zhang <qiangqing.zhang@nxp.com>
>>>>>> ---
>>>>>> drivers/net/phy/phy_device.c | 7 +++++++
>>>>>> 1 file changed, 7 insertions(+)
>>>>>>
>>>>>> diff --git a/drivers/net/phy/phy_device.c
>>>>>> b/drivers/net/phy/phy_device.c index cc38e326405a..312a6f662481
>>>>>> 100644
>>>>>> --- a/drivers/net/phy/phy_device.c
>>>>>> +++ b/drivers/net/phy/phy_device.c
>>>>>> @@ -306,6 +306,13 @@ static __maybe_unused int
>> mdio_bus_phy_resume(struct device *dev)
>>>>>> ret = phy_resume(phydev);
>>>>>> if (ret < 0)
>>>>>> return ret;
>>>>>> +
>>>>>> + /* PHY state could be changed to PHY_NOLINK from MAC controller
>> resume
>>>>>> + * rounte with phy_start(), here change to PHY_UP after
>> re-initializing
>>>>>> + * PHY hardware, let PHY state machine to start/config auto-nego
>> again.
>>>>>> + */
>>>>>> + phydev->state = PHY_UP;
>>>>>> +
>>>>>> no_resume:
>>>>>> if (phydev->attached_dev && phydev->adjust_link)
>>>>>> phy_start_machine(phydev);
>>>>>>
>>>>>
>>>>
>>>
>>
>> This is a quick draft of the modified soft reset for KSZ8081.
>> Some tests would be appreciated.
>>
>
> I test this patch at my side, unfortunately, it still can't work.
>
> I have not found what soft reset would affect in 8081 spec, is there ang common
> Description for different PHYs?
>

You can check the clause 22 spec: 802.3 22.2.4.1.1

Apart from that you can check BMCR value and which modes your PHY advertises
after a soft reset. If the PHY indeed wouldn't restart aneg after a soft reset,
then it would be the only one with this behavior I know. And I'd wonder why
there aren't more such reports.

> Best Regards,
> Joakim Zhang
>> diff --git a/drivers/net/phy/micrel.c b/drivers/net/phy/micrel.c index
>> a14a00328..4902235a8 100644
>> --- a/drivers/net/phy/micrel.c
>> +++ b/drivers/net/phy/micrel.c
>> @@ -1091,6 +1091,42 @@ static void kszphy_get_stats(struct phy_device
>> *phydev,
>> data[i] = kszphy_get_stat(phydev, i); }
>>
>> +int ksz8081_soft_reset(struct phy_device *phydev) {
>> + int bmcr, ret, val;
>> +
>> + phy_lock_mdio_bus(phydev);
>> +
>> + bmcr = __phy_read(phydev, MII_BMCR);
>> + if (bmcr < 0)
>> + return bmcr;
>> +
>> + bmcr |= BMCR_RESET;
>> +
>> + if (bmcr & BMCR_PDOWN)
>> + __phy_write(phydev, MII_BMCR, bmcr);
>> +
>> + if (phydev->autoneg == AUTONEG_ENABLE)
>> + bmcr |= BMCR_ANRESTART;
>> +
>> + __phy_write(phydev, MII_BMCR, bmcr & ~BMCR_ISOLATE);
>> +
>> + phy_unlock_mdio_bus(phydev);
>> +
>> + phydev->suspended = 0;
>> +
>> + ret = phy_read_poll_timeout(phydev, MII_BMCR, val, !(val &
>> BMCR_RESET),
>> + 50000, 600000, true);
>> + if (ret)
>> + return ret;
>> +
>> + /* BMCR may be reset to defaults */
>> + if (phydev->autoneg == AUTONEG_DISABLE)
>> + ret = genphy_setup_forced(phydev);
>> +
>> + return ret;
>> +}
>> +
>> static int kszphy_suspend(struct phy_device *phydev) {
>> /* Disable PHY Interrupts */
>> @@ -1303,7 +1339,7 @@ static struct phy_driver ksphy_driver[] = {
>> .driver_data = &ksz8081_type,
>> .probe = kszphy_probe,
>> .config_init = ksz8081_config_init,
>> - .soft_reset = genphy_soft_reset,
>> + .soft_reset = ksz8081_soft_reset,
>> .config_intr = kszphy_config_intr,
>> .handle_interrupt = kszphy_handle_interrupt,
>> .get_sset_count = kszphy_get_sset_count,
>> --
>> 2.31.1
>

\
 
 \ /