lkml.org 
[lkml]   [2021]   [Feb]   [5]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH v3 5/5] serial: 8250_dw: add em485 support
From
Date
Il 02/02/2021 12:22, Andy Shevchenko ha scritto:
> On Tue, Feb 02, 2021 at 01:31:17AM +0100, Giulio Benetti wrote:
>> Il 18/05/2020 17:21, Andy Shevchenko ha scritto:
>>> On Sun, May 17, 2020 at 11:56:10PM +0200, Heiko Stuebner wrote:
>>>> From: Giulio Benetti <giulio.benetti@micronovasrl.com>
>>>>
>>>> Need to use rs485 transceiver so let's use existing em485 485 emulation
>>>> layer on top of 8250.
>>>>
>>>> Add rs485_config callback to port and uses the standard em485 start and
>>>> stop helpers.
>>>
>>> Would it prevent to use native RS485 support?
>>
>> 8250_dw doesn't have a native RS485 support, do you mean using hardware
>> RTS assertion? Anyway at the moment it's not present. This would be the
>> first rs485 support added to 8250_dw.
>
> DW v4.0+ has it.

I have access to datasheet of DW v3, and I don't have access to hardware
with DW v4.0v Uart.
But I could add rs485emu for only UART version < 4.0 and I can find Uart
version by reading UCV register, would it be acceptable?

Best regards
--
Giulio Benetti
CTO

MICRONOVA SRL
Sede: Via A. Niedda 3 - 35010 Vigonza (PD)
Tel. 049/8931563 - Fax 049/8931346
Cod.Fiscale - P.IVA 02663420285
Capitale Sociale € 26.000 i.v.
Iscritta al Reg. Imprese di Padova N. 02663420285
Numero R.E.A. 258642

\
 
 \ /
  Last update: 2021-02-05 19:55    [W:0.430 / U:0.008 seconds]