Messages in this thread | | | Date | Tue, 2 Nov 2021 17:29:21 +0100 | From | Sebastian Reichel <> | Subject | Re: [PATCH 04/13] power: supply: bq25890: Fix initial setting of the F_CONV_RATE field |
| |
Hi,
On Sat, Oct 30, 2021 at 08:28:04PM +0200, Hans de Goede wrote: > The code doing the initial setting of the F_CONV_RATE field based > on the bq->state.online flag. In order for this to work properly, > this must be done after the initial bq25890_get_chip_state() call. > > Signed-off-by: Hans de Goede <hdegoede@redhat.com> > ---
Thanks, queued.
-- Sebastian
> drivers/power/supply/bq25890_charger.c | 10 +++++----- > 1 file changed, 5 insertions(+), 5 deletions(-) > > diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c > index 491d36a3811a..99497fdc73da 100644 > --- a/drivers/power/supply/bq25890_charger.c > +++ b/drivers/power/supply/bq25890_charger.c > @@ -682,16 +682,16 @@ static int bq25890_hw_init(struct bq25890_device *bq) > } > } > > - /* Configure ADC for continuous conversions when charging */ > - ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online); > + ret = bq25890_get_chip_state(bq, &bq->state); > if (ret < 0) { > - dev_dbg(bq->dev, "Config ADC failed %d\n", ret); > + dev_dbg(bq->dev, "Get state failed %d\n", ret); > return ret; > } > > - ret = bq25890_get_chip_state(bq, &bq->state); > + /* Configure ADC for continuous conversions when charging */ > + ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online); > if (ret < 0) { > - dev_dbg(bq->dev, "Get state failed %d\n", ret); > + dev_dbg(bq->dev, "Config ADC failed %d\n", ret); > return ret; > } > > -- > 2.31.1 > [unhandled content-type:application/pgp-signature] | |