Messages in this thread | | | Date | Mon, 4 Jan 2021 18:31:05 +0100 | From | Andrew Lunn <> | Subject | Re: [PATCH] [RFC] net: phy: Fix reboot crash if CONFIG_IP_PNP is not set |
| |
> The basic rules here should be, if the MDIO bus is registered, it is > usable. There are things like PHY statistics, HWMON temperature > sensors, etc, DSA switches, all which have a life cycle separate to > the interface being up.
[Goes and looks at the code]
Yes, this is runtime PM which is broken.
sh_mdio_init() needs to wrap the mdp->mii_bus->read and mdp->mii_bus->write calls with calls to
pm_runtime_get_sync(&mdp->pdev->dev);
and
pm_runtime_put_sync(&mdp->pdev->dev);
The KSZ8041RNLI supports statistics, which ethtool --phy-stats can read, and these will also going to cause problems.