Subject[PATCH v3] iio: bmp280: fix compensation of humidity
Limit the output of humidity compensation to the range between 0 and 100
percent.

Depending on the calibration parameters of the individual sensor it
happens, that a humidity above 100 percent or below 0 percent is
calculated, which don't make sense in terms of relative humidity.

Add a clamp to the compensation formula as described in the datasheet of
the sensor in chapter 4.2.3.

Although this clamp is documented, it was never in the driver of the
kernel.

It depends on the circumstances (calibration parameters, temperature,
humidity) if one can see a value above 100 percent without the clamp.
The writer of this patch was working with this type of sensor without
noting this error. So it seems to be a rare event when this bug occures.

Signed-off-by: Andreas Klinger <ak@it-klinger.de>
---

Change to v2:
Thanks to the review of Jonathan a more descriptive commit message is
added.

Change to v1:
Thanks to Tomasz for suggesting the easier to use function clamp_val()
which is now used.

drivers/iio/pressure/bmp280-core.c | 2 ++
1 file changed, 2 insertions(+)

diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 29c209cc1108..297ee2205bf6 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -271,6 +271,8 @@ static u32 bmp280_compensate_humidity(struct bmp280_data *data,
+ (s32)2097152) * calib->H2 + 8192) >> 14);
var -= ((((var >> 15) * (var >> 15)) >> 7) * (s32)calib->H1) >> 4;

+ var = clamp_val(var, 0, 419430400);
+
return var >> 12;
};

--
2.20.1
\
 
 \ /