SubjectRe: [PATCH] sdhci: tegra: Avoid reading autocal timeout values when not applicable
From
Date
20.05.2020 23:08, Sowjanya Komatineni пишет:
> When auto calibration timeouts, calibration is disabled and fail-safe
> drive strength values are programmed based on the signal voltage.
>
> Different fail-safe drive strength values based on voltage are
> applicable only for SoCs supporting 3V3 and 1V8 pad controls.
>
> So, this patch avoids reading these properties from the device tree
> for SoCs not using pad controls and the warning of missing properties
> will not show up on these SoC platforms.
>
> Signed-off-by: Sowjanya Komatineni <skomatineni@nvidia.com>
> ---
> drivers/mmc/host/sdhci-tegra.c | 57 ++++++++++++++++++++++++------------------
> 1 file changed, 33 insertions(+), 24 deletions(-)

Hello Sowjanya,

Thank you for the patch.

Tested-by: Dmitry Osipenko <digetx@gmail.com>

\
 
 \ /