Messages in this thread | | | From | Christian Herber <> | Subject | RE: Re: signal quality and cable diagnostic | Date | Mon, 11 May 2020 19:32:05 +0000 |
| |
On May 11, 2020 4:33:53 PM Andrew Lunn <andrew@lunn.ch> wrote: > > Are the classes part of the Open Alliance specification? Ideally we > want to report something standardized, not something proprietary to > NXP. > > Andrew
Hi Andrew,
Such mechanisms are standardized and supported by pretty much all devices in the market. The Open Alliance specification is publicly available here: http://www.opensig.org/download/document/218/Advanced_PHY_features_for_automotive_Ethernet_V1.0.pdf
As the specification is newer than the 100BASE-T1 spec, do not expect first generation devices to follow the register definitions as per Open Alliance. But for future devices, also registers should be same across different vendors.