lkml.org 
[lkml]   [2020]   [Dec]   [17]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH v2 23/48] soc/tegra: pmc: Pulse resets after removing power clamp
Date
The GR3D1 hardware unit needs to pulse hardware reset after removing power
clamp, otherwise reset won't be deasserted. Hence give reset a pulse after
removing the clamp. This stayed unnoticed previously because power
management wasn't supported by the 3D driver until recently and all power
gates are usually ungated after bootloader by default.

Signed-off-by: Dmitry Osipenko <digetx@gmail.com>
---
drivers/soc/tegra/pmc.c | 8 ++++++++
1 file changed, 8 insertions(+)

diff --git a/drivers/soc/tegra/pmc.c b/drivers/soc/tegra/pmc.c
index fd2ba3c59178..985373ce52b1 100644
--- a/drivers/soc/tegra/pmc.c
+++ b/drivers/soc/tegra/pmc.c
@@ -654,6 +654,14 @@ static int tegra_powergate_power_up(struct tegra_powergate *pg,

usleep_range(10, 20);

+ /*
+ * Some hardware blocks may need a 0->1->0 reset pulse in order
+ * to propagate the reset, Tegra30 3D1 is one example.
+ */
+ err = reset_control_reset(pg->reset);
+ if (err)
+ goto powergate_off;
+
if (pg->pmc->soc->needs_mbist_war)
err = tegra210_clk_handle_mbist_war(pg->id);
if (err)
--
2.29.2
\
 
 \ /
  Last update: 2020-12-17 19:12    [W:0.440 / U:0.104 seconds]