SubjectRe: [PATCH RFC 0/8] Introduce warming in thermal framework
From
Date
On 19/10/2020 20:42, Thara Gopinath wrote:
> On Wed, 16 Sep 2020 at 23:22, Thara Gopinath <thara.gopinath@linaro.org> wrote:
>>
>> Thermal framework today supports monitoring for rising temperatures and
>> subsequently initiating cooling action in case of a thermal trip point
>> being crossed. There are scenarios where a SoC need warming mitigating
>> action to be activated if the temperature falls below a cetain permissible
>> limit. Since warming action can be considered mirror opposite of cooling
>> action, most of the thermal framework can be re-used to achieve this. The
>> key assumption in this patch series is that a device can act either as a
>> warming device or a cooling device and not as both.
>>
>> In order to support warming three extensions are needed in the thermal
>> framework.
>>
>> 1. Indication that a trip point is being monitored for falling temperature
>> and not rising temperature. We discussed two different ways to achieve this
>> during LPC. First option is to introduce a new trip type to indicate that a
>> trip is a cold trip(THERMAL_TRIP_COLD). The second option is to introduce a
>> new property for trip point that will indicate whether a trip point is
>> being monitored for rising temperature or falling temperature. The patch
>> series(patches 1-4) chooses the second approach since it allows trip points
>> of any type to be monitored for rising or falling temperature.Also this was
>> the preferred approach when discussed during LPC. The approach that
>> introduces a new cold trip type was posted on the list earlier as a RFC and
>> can be found at [1].
>>
>> 2. Extend the exisitng governors to handle monitoring of falling
>> temperature. The patch series(patches 5 & 6) extends the step wise governor
>> to monitor the falling temperature.Other governors return doing nothing if
>> the trip point they are being called for is being monitored for falling
>> temperature. The governors' mitigate function is called "throttle" in the
>> thermal framework and with this patch series it is a misnomer as the
>> function is called for both throttling and warming up. Ideally
>> "throttle" should be renamed to "mitigate" to improve readability of code.
>> The renaming is not part of this series.
>>
>> 3. Finally, the cooling device framework itself can be reused for a warming
>> device. As stated before a device can act either as a warming device or a
>> cooling device and not as both. With this the cooling state in the
>> framework can be considered as mitigating state with 0 as the state with no
>> thermal mitigation and higher the number higher the thermal mitigation.
>> Again what affects the code readability and comprehension is the term
>> "cooling" which is a misnomer here. Ideally the term "cooling" should be
>> renamed to "mitigating" and hence thermal_cooling_device will become
>> thermal_mitgating_device. The renaming is not part of the patch series as
>> even though the renaming is a simple search-replace, it will change a lot
>> of files. The patch series(patches 7 & 8) instead introduces a minimal set
>> of _warming_device_ apis to register and unregister warming devices which
>> internally is identical to the _cooling_device_ counterpart.
>
> Gentle ping for review..

Pong, review before the end of this week.



--
<http://www.linaro.org/> Linaro.org │ Open source software for ARM SoCs

Follow Linaro: <http://www.facebook.com/pages/Linaro> Facebook |
<http://twitter.com/#!/linaroorg> Twitter |
<http://www.linaro.org/linaro-blog/> Blog

\
 
 \ /
  Last update: 2020-10-19 21:24    [W:0.133 / U:0.948 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site