lkml.org 
[lkml]   [2019]   [Aug]   [8]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH] iio: chemical: bme680: Fix pressure and humidity ABI mismatch
Date
Standard ABI for reporting pressure is kilopascal and for
relative humidity it is millipercent.

What: /sys/bus/iio/devices/iio:deviceX/in_pressureY_input
What: /sys/bus/iio/devices/iio:deviceX/in_pressure_input
KernelVersion: 3.8
Contact: linux-iio@vger.kernel.org
Description:
Scaled pressure measurement from channel Y, in kilopascal.

What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_input
KernelVersion: 3.14
Contact: linux-iio@vger.kernel.org
Description:
Scaled humidity measurement in milli percent.

Currently pressure is reported in hectopascal(hPa) and relative humidity
in percent. Hence fix this ABI mismatch conforming to the standard ABI.

Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor")
Signed-off-by: Himanshu Jha <himanshujha199640@gmail.com>
---

While cleaning this mess I wonder about the gas channel and there
exists no `in_resistance_input` in standard ABI :-(

We only have:

What: /sys/bus/iio/devices/iio:deviceX/in_resistance_raw
What: /sys/bus/iio/devices/iio:deviceX/in_resistanceX_raw
What: /sys/bus/iio/devices/iio:deviceX/out_resistance_raw
What: /sys/bus/iio/devices/iio:deviceX/out_resistanceX_raw
KernelVersion: 4.3
Contact: linux-iio@vger.kernel.org
Description:
Raw (unscaled no offset etc.) resistance reading that can be processed
into an ohm value.

The sensor outputs processed value which is reported as is.

So, does it need a new ABI ?

drivers/iio/chemical/bme680_core.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/iio/chemical/bme680_core.c b/drivers/iio/chemical/bme680_core.c
index ccde4c65ff93..28cc96d1e3c8 100644
--- a/drivers/iio/chemical/bme680_core.c
+++ b/drivers/iio/chemical/bme680_core.c
@@ -670,7 +670,7 @@ static int bme680_read_press(struct bme680_data *data,
}

*val = bme680_compensate_press(data, adc_press);
- *val2 = 100;
+ *val2 = 1000;
return IIO_VAL_FRACTIONAL;
}

@@ -704,7 +704,7 @@ static int bme680_read_humid(struct bme680_data *data,
comp_humidity = bme680_compensate_humid(data, adc_humidity);

*val = comp_humidity;
- *val2 = 1000;
+ *val2 = 1000000;
return IIO_VAL_FRACTIONAL;
}

--
2.17.1
\
 
 \ /
  Last update: 2019-08-08 17:45    [W:0.037 / U:0.712 seconds]