Messages in this thread | | | Subject | Re: [PATCH 2/3] dt: lm3532: Add property for full scale current. | From | Jacek Anaszewski <> | Date | Thu, 1 Aug 2019 20:53:33 +0200 |
| |
Dan,
On 8/1/19 5:14 PM, Dan Murphy wrote: > Add a property for each control bank to configure the > full scale current setting for the device. > > Signed-off-by: Dan Murphy <dmurphy@ti.com> > --- > Documentation/devicetree/bindings/leds/leds-lm3532.txt | 4 ++++ > 1 file changed, 4 insertions(+) > > diff --git a/Documentation/devicetree/bindings/leds/leds-lm3532.txt b/Documentation/devicetree/bindings/leds/leds-lm3532.txt > index c087f85ddddc..d3498dd24e8e 100644 > --- a/Documentation/devicetree/bindings/leds/leds-lm3532.txt > +++ b/Documentation/devicetree/bindings/leds/leds-lm3532.txt > @@ -62,6 +62,9 @@ Optional LED child properties: > - label : see Documentation/devicetree/bindings/leds/common.txt > - linux,default-trigger : > see Documentation/devicetree/bindings/leds/common.txt > + - ti,fs-current : Defines the full scale current value for each control > + bank. The range is from 5000uA-29800uA in increments > + of 800uA.
Wouldn't led-max-microamp fit here?
> > Example: > led-controller@38 { > @@ -85,6 +88,7 @@ led-controller@38 { > reg = <0>; > led-sources = <2>; > ti,led-mode = <1>; > + ti,fs-current = <21800>; > label = ":backlight"; > linux,default-trigger = "backlight"; > }; >
-- Best regards, Jacek Anaszewski
| |