Messages in this thread | | | From | Fabio Estevam <> | Date | Wed, 17 Jul 2019 13:50:02 -0300 | Subject | Re: [PATCH v4 6/6] ASoC: sgtl5000: Fix charge pump source assignment |
| |
On Wed, Jul 17, 2019 at 1:30 PM Oleksandr Suvorov <oleksandr.suvorov@toradex.com> wrote: > > If VDDA != VDDIO and any of them is greater than 3.1V, charge pump > source can be assigned automatically [1]. > > [1] https://www.nxp.com/docs/en/data-sheet/SGTL5000.pdf > > Signed-off-by: Oleksandr Suvorov <oleksandr.suvorov@toradex.com> > Reviewed-by: Marcel Ziswiler <marcel.ziswiler@toradex.com> > Reviewed-by: Igor Opaniuk <igor.opaniuk@toradex.com>
Reviewed-by: Fabio Estevam <festevam@gmail.com>
| |