Messages in this thread Patch in this message | | | From | Sasha Levin <> | Subject | [PATCH AUTOSEL 4.19 23/36] platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table | Date | Tue, 4 Jun 2019 19:23:18 -0400 |
| |
From: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
[ Upstream commit d6423bd03031c020121da26c41a26bd5cc6d0da3 ]
There are several Beckhoff Automation industrial PC boards which use pmc_plt_clk* clocks for ethernet controllers. This adds affected boards to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and not turned off.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Sasha Levin <sashal@kernel.org> --- drivers/platform/x86/pmc_atom.c | 24 ++++++++++++++++++++++++ 1 file changed, 24 insertions(+)
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index a311f48ce7c9..b1d804376237 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), }, }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB3163", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB3163"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6263", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6263"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6363", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6363"), + }, + }, { /*sentinel*/ } }; -- 2.20.1
| |