lkml.org 
[lkml]   [2019]   [Apr]   [24]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH v2 00/13] qcom: dts: thermal cleanups
From
Date
On 23/04/2019 15:10, Marc Gonzalez wrote:

> Sure. I can give you a Tested-by once everything works on the MEDIABOX I have.
>
> You mention the 4 thermal_zone*/temp failures.
>
> What about the cluster0-mhm-thermal and cluster1-mhm-thermal failures?

I have synced up with today's linux-next.

# dmesg | grep thermal
Failed to build cluster0-mhm-thermal zone -22
Failed to build cluster1-mhm-thermal zone -22

# for F in $(find /sys/class/thermal/thermal_zone?/ /sys/class/thermal/thermal_zone??/ -type f); do echo $F; cat $F; done
/sys/class/thermal/thermal_zone0/uevent
/sys/class/thermal/thermal_zone0/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone0/mode
enabled
/sys/class/thermal/thermal_zone0/power/runtime_active_time
0
/sys/class/thermal/thermal_zone0/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone0/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone0/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone0/power/control
auto
/sys/class/thermal/thermal_zone0/available_policies
step_wise
/sys/class/thermal/thermal_zone0/policy
step_wise
/sys/class/thermal/thermal_zone0/trip_point_1_type
critical
/sys/class/thermal/thermal_zone0/k_d
0
/sys/class/thermal/thermal_zone0/sustainable_power
0
/sys/class/thermal/thermal_zone0/type
cpu0-thermal
/sys/class/thermal/thermal_zone0/offset
0
/sys/class/thermal/thermal_zone0/slope
1
/sys/class/thermal/thermal_zone0/trip_point_0_type
passive
/sys/class/thermal/thermal_zone0/k_po
0
/sys/class/thermal/thermal_zone0/integral_cutoff
0
/sys/class/thermal/thermal_zone0/k_i
0
/sys/class/thermal/thermal_zone0/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone0/k_pu
0
/sys/class/thermal/thermal_zone0/temp
34900
/sys/class/thermal/thermal_zone0/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone0/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone1/uevent
/sys/class/thermal/thermal_zone1/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone1/mode
enabled
/sys/class/thermal/thermal_zone1/power/runtime_active_time
0
/sys/class/thermal/thermal_zone1/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone1/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone1/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone1/power/control
auto
/sys/class/thermal/thermal_zone1/available_policies
step_wise
/sys/class/thermal/thermal_zone1/policy
step_wise
/sys/class/thermal/thermal_zone1/trip_point_1_type
critical
/sys/class/thermal/thermal_zone1/k_d
0
/sys/class/thermal/thermal_zone1/sustainable_power
0
/sys/class/thermal/thermal_zone1/type
cpu1-thermal
/sys/class/thermal/thermal_zone1/offset
0
/sys/class/thermal/thermal_zone1/slope
1
/sys/class/thermal/thermal_zone1/trip_point_0_type
passive
/sys/class/thermal/thermal_zone1/k_po
0
/sys/class/thermal/thermal_zone1/integral_cutoff
0
/sys/class/thermal/thermal_zone1/k_i
0
/sys/class/thermal/thermal_zone1/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone1/k_pu
0
/sys/class/thermal/thermal_zone1/temp
33900
/sys/class/thermal/thermal_zone1/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone1/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone2/uevent
/sys/class/thermal/thermal_zone2/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone2/mode
enabled
/sys/class/thermal/thermal_zone2/power/runtime_active_time
0
/sys/class/thermal/thermal_zone2/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone2/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone2/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone2/power/control
auto
/sys/class/thermal/thermal_zone2/available_policies
step_wise
/sys/class/thermal/thermal_zone2/policy
step_wise
/sys/class/thermal/thermal_zone2/trip_point_1_type
critical
/sys/class/thermal/thermal_zone2/k_d
0
/sys/class/thermal/thermal_zone2/sustainable_power
0
/sys/class/thermal/thermal_zone2/type
cpu2-thermal
/sys/class/thermal/thermal_zone2/offset
0
/sys/class/thermal/thermal_zone2/slope
1
/sys/class/thermal/thermal_zone2/trip_point_0_type
passive
/sys/class/thermal/thermal_zone2/k_po
0
/sys/class/thermal/thermal_zone2/integral_cutoff
0
/sys/class/thermal/thermal_zone2/k_i
0
/sys/class/thermal/thermal_zone2/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone2/k_pu
0
/sys/class/thermal/thermal_zone2/temp
34200
/sys/class/thermal/thermal_zone2/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone2/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone3/uevent
/sys/class/thermal/thermal_zone3/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone3/mode
enabled
/sys/class/thermal/thermal_zone3/power/runtime_active_time
0
/sys/class/thermal/thermal_zone3/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone3/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone3/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone3/power/control
auto
/sys/class/thermal/thermal_zone3/available_policies
step_wise
/sys/class/thermal/thermal_zone3/policy
step_wise
/sys/class/thermal/thermal_zone3/trip_point_1_type
critical
/sys/class/thermal/thermal_zone3/k_d
0
/sys/class/thermal/thermal_zone3/sustainable_power
0
/sys/class/thermal/thermal_zone3/type
cpu3-thermal
/sys/class/thermal/thermal_zone3/offset
0
/sys/class/thermal/thermal_zone3/slope
1
/sys/class/thermal/thermal_zone3/trip_point_0_type
passive
/sys/class/thermal/thermal_zone3/k_po
0
/sys/class/thermal/thermal_zone3/integral_cutoff
0
/sys/class/thermal/thermal_zone3/k_i
0
/sys/class/thermal/thermal_zone3/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone3/k_pu
0
/sys/class/thermal/thermal_zone3/temp
34200
/sys/class/thermal/thermal_zone3/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone3/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone4/uevent
/sys/class/thermal/thermal_zone4/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone4/mode
enabled
/sys/class/thermal/thermal_zone4/power/runtime_active_time
0
/sys/class/thermal/thermal_zone4/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone4/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone4/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone4/power/control
auto
/sys/class/thermal/thermal_zone4/available_policies
step_wise
/sys/class/thermal/thermal_zone4/policy
step_wise
/sys/class/thermal/thermal_zone4/trip_point_1_type
critical
/sys/class/thermal/thermal_zone4/k_d
0
/sys/class/thermal/thermal_zone4/sustainable_power
0
/sys/class/thermal/thermal_zone4/type
cpu4-thermal
/sys/class/thermal/thermal_zone4/offset
0
/sys/class/thermal/thermal_zone4/slope
1
/sys/class/thermal/thermal_zone4/trip_point_0_type
passive
/sys/class/thermal/thermal_zone4/k_po
0
/sys/class/thermal/thermal_zone4/integral_cutoff
0
/sys/class/thermal/thermal_zone4/k_i
0
/sys/class/thermal/thermal_zone4/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone4/k_pu
0
/sys/class/thermal/thermal_zone4/temp
34200
/sys/class/thermal/thermal_zone4/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone4/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone5/uevent
/sys/class/thermal/thermal_zone5/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone5/mode
enabled
/sys/class/thermal/thermal_zone5/power/runtime_active_time
0
/sys/class/thermal/thermal_zone5/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone5/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone5/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone5/power/control
auto
/sys/class/thermal/thermal_zone5/available_policies
step_wise
/sys/class/thermal/thermal_zone5/policy
step_wise
/sys/class/thermal/thermal_zone5/trip_point_1_type
critical
/sys/class/thermal/thermal_zone5/k_d
0
/sys/class/thermal/thermal_zone5/sustainable_power
0
/sys/class/thermal/thermal_zone5/type
cpu5-thermal
/sys/class/thermal/thermal_zone5/offset
0
/sys/class/thermal/thermal_zone5/slope
1
/sys/class/thermal/thermal_zone5/trip_point_0_type
passive
/sys/class/thermal/thermal_zone5/k_po
0
/sys/class/thermal/thermal_zone5/integral_cutoff
0
/sys/class/thermal/thermal_zone5/k_i
0
/sys/class/thermal/thermal_zone5/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone5/k_pu
0
/sys/class/thermal/thermal_zone5/temp
32900
/sys/class/thermal/thermal_zone5/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone5/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone6/uevent
/sys/class/thermal/thermal_zone6/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone6/mode
enabled
/sys/class/thermal/thermal_zone6/power/runtime_active_time
0
/sys/class/thermal/thermal_zone6/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone6/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone6/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone6/power/control
auto
/sys/class/thermal/thermal_zone6/available_policies
step_wise
/sys/class/thermal/thermal_zone6/policy
step_wise
/sys/class/thermal/thermal_zone6/trip_point_1_type
critical
/sys/class/thermal/thermal_zone6/k_d
0
/sys/class/thermal/thermal_zone6/sustainable_power
0
/sys/class/thermal/thermal_zone6/type
cpu6-thermal
/sys/class/thermal/thermal_zone6/offset
0
/sys/class/thermal/thermal_zone6/slope
1
/sys/class/thermal/thermal_zone6/trip_point_0_type
passive
/sys/class/thermal/thermal_zone6/k_po
0
/sys/class/thermal/thermal_zone6/integral_cutoff
0
/sys/class/thermal/thermal_zone6/k_i
0
/sys/class/thermal/thermal_zone6/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone6/k_pu
0
/sys/class/thermal/thermal_zone6/temp
33300
/sys/class/thermal/thermal_zone6/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone6/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone7/uevent
/sys/class/thermal/thermal_zone7/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone7/mode
enabled
/sys/class/thermal/thermal_zone7/power/runtime_active_time
0
/sys/class/thermal/thermal_zone7/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone7/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone7/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone7/power/control
auto
/sys/class/thermal/thermal_zone7/available_policies
step_wise
/sys/class/thermal/thermal_zone7/policy
step_wise
/sys/class/thermal/thermal_zone7/trip_point_1_type
critical
/sys/class/thermal/thermal_zone7/k_d
0
/sys/class/thermal/thermal_zone7/sustainable_power
0
/sys/class/thermal/thermal_zone7/type
cpu7-thermal
/sys/class/thermal/thermal_zone7/offset
0
/sys/class/thermal/thermal_zone7/slope
1
/sys/class/thermal/thermal_zone7/trip_point_0_type
passive
/sys/class/thermal/thermal_zone7/k_po
0
/sys/class/thermal/thermal_zone7/integral_cutoff
0
/sys/class/thermal/thermal_zone7/k_i
0
/sys/class/thermal/thermal_zone7/trip_point_1_temp
110000
/sys/class/thermal/thermal_zone7/k_pu
0
/sys/class/thermal/thermal_zone7/temp
34200
/sys/class/thermal/thermal_zone7/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone7/trip_point_0_temp
75000
/sys/class/thermal/thermal_zone8/uevent
/sys/class/thermal/thermal_zone8/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone8/passive
0
/sys/class/thermal/thermal_zone8/mode
disabled
/sys/class/thermal/thermal_zone8/power/runtime_active_time
0
/sys/class/thermal/thermal_zone8/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone8/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone8/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone8/power/control
auto
/sys/class/thermal/thermal_zone8/available_policies
step_wise
/sys/class/thermal/thermal_zone8/policy
step_wise
/sys/class/thermal/thermal_zone8/k_d
0
/sys/class/thermal/thermal_zone8/sustainable_power
0
/sys/class/thermal/thermal_zone8/type
gpu-thermal-bottom
/sys/class/thermal/thermal_zone8/offset
0
/sys/class/thermal/thermal_zone8/slope
1
/sys/class/thermal/thermal_zone8/trip_point_0_type
hot
/sys/class/thermal/thermal_zone8/k_po
0
/sys/class/thermal/thermal_zone8/integral_cutoff
0
/sys/class/thermal/thermal_zone8/k_i
0
/sys/class/thermal/thermal_zone8/k_pu
0
/sys/class/thermal/thermal_zone8/temp
cat: read error: Invalid argument
/sys/class/thermal/thermal_zone8/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone9/uevent
/sys/class/thermal/thermal_zone9/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone9/passive
0
/sys/class/thermal/thermal_zone9/mode
disabled
/sys/class/thermal/thermal_zone9/power/runtime_active_time
0
/sys/class/thermal/thermal_zone9/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone9/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone9/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone9/power/control
auto
/sys/class/thermal/thermal_zone9/available_policies
step_wise
/sys/class/thermal/thermal_zone9/policy
step_wise
/sys/class/thermal/thermal_zone9/k_d
0
/sys/class/thermal/thermal_zone9/sustainable_power
0
/sys/class/thermal/thermal_zone9/type
gpu-thermal-top
/sys/class/thermal/thermal_zone9/offset
0
/sys/class/thermal/thermal_zone9/slope
1
/sys/class/thermal/thermal_zone9/trip_point_0_type
hot
/sys/class/thermal/thermal_zone9/k_po
0
/sys/class/thermal/thermal_zone9/integral_cutoff
0
/sys/class/thermal/thermal_zone9/k_i
0
/sys/class/thermal/thermal_zone9/k_pu
0
/sys/class/thermal/thermal_zone9/temp
cat: read error: Invalid argument
/sys/class/thermal/thermal_zone9/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone10/uevent
/sys/class/thermal/thermal_zone10/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone10/passive
0
/sys/class/thermal/thermal_zone10/mode
enabled
/sys/class/thermal/thermal_zone10/power/runtime_active_time
0
/sys/class/thermal/thermal_zone10/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone10/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone10/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone10/power/control
auto
/sys/class/thermal/thermal_zone10/available_policies
step_wise
/sys/class/thermal/thermal_zone10/policy
step_wise
/sys/class/thermal/thermal_zone10/k_d
0
/sys/class/thermal/thermal_zone10/sustainable_power
0
/sys/class/thermal/thermal_zone10/type
cluster1-l2-thermal
/sys/class/thermal/thermal_zone10/offset
0
/sys/class/thermal/thermal_zone10/slope
1
/sys/class/thermal/thermal_zone10/trip_point_0_type
hot
/sys/class/thermal/thermal_zone10/k_po
0
/sys/class/thermal/thermal_zone10/integral_cutoff
0
/sys/class/thermal/thermal_zone10/k_i
0
/sys/class/thermal/thermal_zone10/k_pu
0
/sys/class/thermal/thermal_zone10/temp
32900
/sys/class/thermal/thermal_zone10/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone11/uevent
/sys/class/thermal/thermal_zone11/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone11/passive
0
/sys/class/thermal/thermal_zone11/mode
enabled
/sys/class/thermal/thermal_zone11/power/runtime_active_time
0
/sys/class/thermal/thermal_zone11/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone11/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone11/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone11/power/control
auto
/sys/class/thermal/thermal_zone11/available_policies
step_wise
/sys/class/thermal/thermal_zone11/policy
step_wise
/sys/class/thermal/thermal_zone11/k_d
0
/sys/class/thermal/thermal_zone11/sustainable_power
0
/sys/class/thermal/thermal_zone11/type
modem-thermal
/sys/class/thermal/thermal_zone11/offset
0
/sys/class/thermal/thermal_zone11/slope
1
/sys/class/thermal/thermal_zone11/trip_point_0_type
hot
/sys/class/thermal/thermal_zone11/k_po
0
/sys/class/thermal/thermal_zone11/integral_cutoff
0
/sys/class/thermal/thermal_zone11/k_i
0
/sys/class/thermal/thermal_zone11/k_pu
0
/sys/class/thermal/thermal_zone11/temp
33200
/sys/class/thermal/thermal_zone11/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone12/uevent
/sys/class/thermal/thermal_zone12/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone12/passive
0
/sys/class/thermal/thermal_zone12/mode
enabled
/sys/class/thermal/thermal_zone12/power/runtime_active_time
0
/sys/class/thermal/thermal_zone12/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone12/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone12/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone12/power/control
auto
/sys/class/thermal/thermal_zone12/available_policies
step_wise
/sys/class/thermal/thermal_zone12/policy
step_wise
/sys/class/thermal/thermal_zone12/k_d
0
/sys/class/thermal/thermal_zone12/sustainable_power
0
/sys/class/thermal/thermal_zone12/type
mem-thermal
/sys/class/thermal/thermal_zone12/offset
0
/sys/class/thermal/thermal_zone12/slope
1
/sys/class/thermal/thermal_zone12/trip_point_0_type
hot
/sys/class/thermal/thermal_zone12/k_po
0
/sys/class/thermal/thermal_zone12/integral_cutoff
0
/sys/class/thermal/thermal_zone12/k_i
0
/sys/class/thermal/thermal_zone12/k_pu
0
/sys/class/thermal/thermal_zone12/temp
32900
/sys/class/thermal/thermal_zone12/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone13/uevent
/sys/class/thermal/thermal_zone13/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone13/passive
0
/sys/class/thermal/thermal_zone13/mode
enabled
/sys/class/thermal/thermal_zone13/power/runtime_active_time
0
/sys/class/thermal/thermal_zone13/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone13/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone13/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone13/power/control
auto
/sys/class/thermal/thermal_zone13/available_policies
step_wise
/sys/class/thermal/thermal_zone13/policy
step_wise
/sys/class/thermal/thermal_zone13/k_d
0
/sys/class/thermal/thermal_zone13/sustainable_power
0
/sys/class/thermal/thermal_zone13/type
wlan-thermal
/sys/class/thermal/thermal_zone13/offset
0
/sys/class/thermal/thermal_zone13/slope
1
/sys/class/thermal/thermal_zone13/trip_point_0_type
hot
/sys/class/thermal/thermal_zone13/k_po
0
/sys/class/thermal/thermal_zone13/integral_cutoff
0
/sys/class/thermal/thermal_zone13/k_i
0
/sys/class/thermal/thermal_zone13/k_pu
0
/sys/class/thermal/thermal_zone13/temp
33200
/sys/class/thermal/thermal_zone13/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone14/uevent
/sys/class/thermal/thermal_zone14/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone14/passive
0
/sys/class/thermal/thermal_zone14/mode
enabled
/sys/class/thermal/thermal_zone14/power/runtime_active_time
0
/sys/class/thermal/thermal_zone14/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone14/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone14/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone14/power/control
auto
/sys/class/thermal/thermal_zone14/available_policies
step_wise
/sys/class/thermal/thermal_zone14/policy
step_wise
/sys/class/thermal/thermal_zone14/k_d
0
/sys/class/thermal/thermal_zone14/sustainable_power
0
/sys/class/thermal/thermal_zone14/type
q6-dsp-thermal
/sys/class/thermal/thermal_zone14/offset
0
/sys/class/thermal/thermal_zone14/slope
1
/sys/class/thermal/thermal_zone14/trip_point_0_type
hot
/sys/class/thermal/thermal_zone14/k_po
0
/sys/class/thermal/thermal_zone14/integral_cutoff
0
/sys/class/thermal/thermal_zone14/k_i
0
/sys/class/thermal/thermal_zone14/k_pu
0
/sys/class/thermal/thermal_zone14/temp
32900
/sys/class/thermal/thermal_zone14/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone15/uevent
/sys/class/thermal/thermal_zone15/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone15/passive
0
/sys/class/thermal/thermal_zone15/mode
enabled
/sys/class/thermal/thermal_zone15/power/runtime_active_time
0
/sys/class/thermal/thermal_zone15/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone15/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone15/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone15/power/control
auto
/sys/class/thermal/thermal_zone15/available_policies
step_wise
/sys/class/thermal/thermal_zone15/policy
step_wise
/sys/class/thermal/thermal_zone15/k_d
0
/sys/class/thermal/thermal_zone15/sustainable_power
0
/sys/class/thermal/thermal_zone15/type
camera-thermal
/sys/class/thermal/thermal_zone15/offset
0
/sys/class/thermal/thermal_zone15/slope
1
/sys/class/thermal/thermal_zone15/trip_point_0_type
hot
/sys/class/thermal/thermal_zone15/k_po
0
/sys/class/thermal/thermal_zone15/integral_cutoff
0
/sys/class/thermal/thermal_zone15/k_i
0
/sys/class/thermal/thermal_zone15/k_pu
0
/sys/class/thermal/thermal_zone15/temp
32200
/sys/class/thermal/thermal_zone15/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone16/uevent
/sys/class/thermal/thermal_zone16/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone16/passive
0
/sys/class/thermal/thermal_zone16/mode
enabled
/sys/class/thermal/thermal_zone16/power/runtime_active_time
0
/sys/class/thermal/thermal_zone16/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone16/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone16/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone16/power/control
auto
/sys/class/thermal/thermal_zone16/available_policies
step_wise
/sys/class/thermal/thermal_zone16/policy
step_wise
/sys/class/thermal/thermal_zone16/k_d
0
/sys/class/thermal/thermal_zone16/sustainable_power
0
/sys/class/thermal/thermal_zone16/type
multimedia-thermal
/sys/class/thermal/thermal_zone16/offset
0
/sys/class/thermal/thermal_zone16/slope
1
/sys/class/thermal/thermal_zone16/trip_point_0_type
hot
/sys/class/thermal/thermal_zone16/k_po
0
/sys/class/thermal/thermal_zone16/integral_cutoff
0
/sys/class/thermal/thermal_zone16/k_i
0
/sys/class/thermal/thermal_zone16/k_pu
0
/sys/class/thermal/thermal_zone16/temp
32900
/sys/class/thermal/thermal_zone16/trip_point_0_temp
90000
/sys/class/thermal/thermal_zone17/uevent
/sys/class/thermal/thermal_zone17/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone17/mode
disabled
/sys/class/thermal/thermal_zone17/power/runtime_active_time
0
/sys/class/thermal/thermal_zone17/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone17/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone17/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone17/power/control
auto
/sys/class/thermal/thermal_zone17/available_policies
step_wise
/sys/class/thermal/thermal_zone17/policy
step_wise
/sys/class/thermal/thermal_zone17/trip_point_1_type
critical
/sys/class/thermal/thermal_zone17/k_d
0
/sys/class/thermal/thermal_zone17/sustainable_power
0
/sys/class/thermal/thermal_zone17/type
pm8998
/sys/class/thermal/thermal_zone17/offset
0
/sys/class/thermal/thermal_zone17/slope
1
/sys/class/thermal/thermal_zone17/trip_point_0_type
passive
/sys/class/thermal/thermal_zone17/k_po
0
/sys/class/thermal/thermal_zone17/integral_cutoff
0
/sys/class/thermal/thermal_zone17/k_i
0
/sys/class/thermal/thermal_zone17/trip_point_1_temp
125000
/sys/class/thermal/thermal_zone17/k_pu
0
/sys/class/thermal/thermal_zone17/temp
cat: read error: Invalid argument
/sys/class/thermal/thermal_zone17/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone17/trip_point_0_temp
105000
/sys/class/thermal/thermal_zone18/uevent
/sys/class/thermal/thermal_zone18/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone18/passive
0
/sys/class/thermal/thermal_zone18/mode
enabled
/sys/class/thermal/thermal_zone18/power/runtime_active_time
0
/sys/class/thermal/thermal_zone18/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone18/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone18/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone18/power/control
auto
/sys/class/thermal/thermal_zone18/available_policies
step_wise
/sys/class/thermal/thermal_zone18/policy
step_wise
/sys/class/thermal/thermal_zone18/k_d
0
/sys/class/thermal/thermal_zone18/sustainable_power
0
/sys/class/thermal/thermal_zone18/type
battery-thermal
/sys/class/thermal/thermal_zone18/offset
0
/sys/class/thermal/thermal_zone18/slope
1
/sys/class/thermal/thermal_zone18/trip_point_0_type
critical
/sys/class/thermal/thermal_zone18/k_po
0
/sys/class/thermal/thermal_zone18/integral_cutoff
0
/sys/class/thermal/thermal_zone18/k_i
0
/sys/class/thermal/thermal_zone18/k_pu
0
/sys/class/thermal/thermal_zone18/temp
34900
/sys/class/thermal/thermal_zone18/trip_point_0_temp
60000
/sys/class/thermal/thermal_zone19/uevent
/sys/class/thermal/thermal_zone19/trip_point_0_hyst
2000
/sys/class/thermal/thermal_zone19/mode
disabled
/sys/class/thermal/thermal_zone19/power/runtime_active_time
0
/sys/class/thermal/thermal_zone19/power/runtime_status
unsupported
/sys/class/thermal/thermal_zone19/power/autosuspend_delay_ms
cat: read error: Input/output error
/sys/class/thermal/thermal_zone19/power/runtime_suspended_time
0
/sys/class/thermal/thermal_zone19/power/control
auto
/sys/class/thermal/thermal_zone19/available_policies
step_wise
/sys/class/thermal/thermal_zone19/policy
step_wise
/sys/class/thermal/thermal_zone19/trip_point_1_type
critical
/sys/class/thermal/thermal_zone19/k_d
0
/sys/class/thermal/thermal_zone19/sustainable_power
0
/sys/class/thermal/thermal_zone19/type
skin-thermal
/sys/class/thermal/thermal_zone19/offset
0
/sys/class/thermal/thermal_zone19/slope
1
/sys/class/thermal/thermal_zone19/trip_point_0_type
passive
/sys/class/thermal/thermal_zone19/k_po
0
/sys/class/thermal/thermal_zone19/integral_cutoff
0
/sys/class/thermal/thermal_zone19/k_i
0
/sys/class/thermal/thermal_zone19/trip_point_1_temp
70000
/sys/class/thermal/thermal_zone19/k_pu
0
/sys/class/thermal/thermal_zone19/temp
cat: read error: Invalid argument
/sys/class/thermal/thermal_zone19/trip_point_1_hyst
2000
/sys/class/thermal/thermal_zone19/trip_point_0_temp
44000

\
 
 \ /
  Last update: 2019-04-24 16:31    [W:0.355 / U:0.060 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site