    Subject[PATCH 4.19 37/96] iio/gyro/bmg160: Use millidegrees for temperature scale
    Date
    From: Mike Looijmans <mike.looijmans@topic.nl>

    commit 40a7198a4a01037003c7ca714f0d048a61e729ac upstream.

    Standard unit for temperature is millidegrees Celcius, whereas this driver
    was reporting in degrees. Fix the scale factor in the driver.

    Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl>
    Cc: <Stable@vger.kernel.org>
    Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
    Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

    ---
    drivers/iio/gyro/bmg160_core.c | 6 +++---
    1 file changed, 3 insertions(+), 3 deletions(-)

    --- a/drivers/iio/gyro/bmg160_core.c
    +++ b/drivers/iio/gyro/bmg160_core.c
    @@ -582,11 +582,10 @@ static int bmg160_read_raw(struct iio_de
    case IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY:
    return bmg160_get_filter(data, val);
    case IIO_CHAN_INFO_SCALE:
    - *val = 0;
    switch (chan->type) {
    case IIO_TEMP:
    - *val2 = 500000;
    - return IIO_VAL_INT_PLUS_MICRO;
    + *val = 500;
    + return IIO_VAL_INT;
    case IIO_ANGL_VEL:
    {
    int i;
    @@ -594,6 +593,7 @@ static int bmg160_read_raw(struct iio_de
    for (i = 0; i < ARRAY_SIZE(bmg160_scale_table); ++i) {
    if (bmg160_scale_table[i].dps_range ==
    data->dps_range) {
    + *val = 0;
    *val2 = bmg160_scale_table[i].scale;
    return IIO_VAL_INT_PLUS_MICRO;
    }

    \
     
     \ /
      Last update: 2019-04-24 19:49    [W:4.110 / U:0.048 seconds]