Messages in this thread | | | Date | Wed, 24 Apr 2019 18:47:09 +0200 | From | Peter Zijlstra <> | Subject | Re: [PATCH V3 3/3] thermal/cpu-cooling: Update thermal pressure in case of a maximum frequency capping |
| |
On Tue, Apr 16, 2019 at 03:38:41PM -0400, Thara Gopinath wrote: > Enable cpufreq cooling device to update the thermal pressure in > event of a capped maximum frequency or removal of capped maximum > frequency. > > Signed-off-by: Thara Gopinath <thara.gopinath@linaro.org> > --- > drivers/thermal/cpu_cooling.c | 4 ++++ > 1 file changed, 4 insertions(+) > > diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c > index 6fff161..d5cc3c3 100644 > --- a/drivers/thermal/cpu_cooling.c > +++ b/drivers/thermal/cpu_cooling.c > @@ -31,6 +31,7 @@ > #include <linux/slab.h> > #include <linux/cpu.h> > #include <linux/cpu_cooling.h> > +#include <linux/sched/thermal.h> > > #include <trace/events/thermal.h> > > @@ -177,6 +178,9 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, > > if (policy->max > clipped_freq) > cpufreq_verify_within_limits(policy, 0, clipped_freq); > + > + sched_update_thermal_pressure(policy->cpus, > + policy->max, policy->cpuinfo.max_freq);
If it's already telling the cpufreq thing, why not get it from sugov instead?
| |