Messages in this thread Patch in this message | | | From | Wolfram Sang <> | Subject | [PATCH v2 15/16] watchdog: xen_wdt: drop warning after calling watchdog_init_timeout | Date | Tue, 16 Apr 2019 12:25:14 +0200 |
| |
The core will print out details now.
Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com> --- drivers/watchdog/xen_wdt.c | 4 +--- 1 file changed, 1 insertion(+), 3 deletions(-)
diff --git a/drivers/watchdog/xen_wdt.c b/drivers/watchdog/xen_wdt.c index f1c016d015b3..d54da2e0f2e1 100644 --- a/drivers/watchdog/xen_wdt.c +++ b/drivers/watchdog/xen_wdt.c @@ -135,9 +135,7 @@ static int xen_wdt_probe(struct platform_device *pdev) return -ENODEV; } - if (watchdog_init_timeout(&xen_wdt_dev, timeout, NULL)) - dev_info(&pdev->dev, "timeout value invalid, using %d\n", - xen_wdt_dev.timeout); + watchdog_init_timeout(&xen_wdt_dev, timeout, NULL); watchdog_set_nowayout(&xen_wdt_dev, nowayout); watchdog_stop_on_reboot(&xen_wdt_dev); watchdog_stop_on_unregister(&xen_wdt_dev); -- 2.11.0
| |