Messages in this thread | | | From | Geert Uytterhoeven <> | Date | Mon, 1 Apr 2019 10:59:32 +0200 | Subject | Re: [PATCH 1/2] rtc: da9063: set range |
| |
Hi Wolfram,
On Mon, Apr 1, 2019 at 10:43 AM Wolfram Sang <wsa@the-dreams.de> wrote: > On Thu, Mar 21, 2019 at 11:15:56AM +0100, Alexandre Belloni wrote: > > The DA9062 and DA9063 have a year register that can go up to 0x3F. > > > > Signed-off-by: Alexandre Belloni <alexandre.belloni@bootlin.com> > > Thanks for this patch! Didn't know about the devm_rtc_device_register() > conversion going on. Glad I learned about it. > > Reviewed-by: Wolfram Sang <wsa+renesas@sang-engineering.com> > > I couldn't test the upper limit (DA9063 hooked to a 32bit system here), > but lower limit works and RTC in general works.
BTW, does the RTC alarm interrupt work for you?
Gr{oetje,eeting}s,
Geert
-- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@linux-m68k.org
In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds
| |